Furnace error codes

What does your furnace error code mean? These are the gas furnace flash codes and display codes from Goodman, Trane, Rheem, Carrier and Lennox manuals. Pick your brand to see what a code means, how to fix it safely and when to call a pro.

Last updated

The boards do not share one code language. On the Carrier 59SC5, status codes are short and long flashes of one LED: code 33 is three short and three long, and it means a limit or flame rollout switch is open. Goodman GR9S96 and GD9S96 show two characters on a 7-segment display, so EE3 is an open primary limit and E11 is an open rollout switch. Lennox ML180UH uses a red LED and a green LED together. Rheem R96V and Trane S9V2 use 7-segment displays (Rheem 33 is an open rollout switch; Trane E04 is an open limit, rollout or reverse-airflow switch). Read the pattern before you cut power. Several of these manuals also store a fault history, which a reset can clear. The longer explanations are in the furnace guides: how to read the light, how a reset works, what a pressure-switch code is asking the draft system to prove, and when a rollout or limit code is a reason to stop and call a technician rather than try another cycle. The winter 2026 no-heat checklist follows those same documents for a furnace that will not heat. The part finder lists a part only when one of these manuals names it on that code. Lennox SL280DFNV is a different display from the ML180 red-and-green chart: a seven-segment LED. E200 is a rollout hard lockout. E223 is the low pressure switch failed open. E250 is the limit circuit open. E270 is a soft lockout after retries with no flame current. E291 is heat airflow below the minimum, and that row names a dirty filter.

Guides for this equipment: Furnace Air Filters: How Often to Change and Why It Matters · Furnace Blowing Cold Air: Common Causes · Furnace Flame Sensor: Symptoms, Codes and Cleaning · Furnace Ignition Lockout: It Tried to Light and Stopped · Furnace Limit Switch Open: Blower Runs, No Heat · Furnace No Heat: Winter 2026 Checklist · Furnace Pressure Switch Error: What It Means · Furnace Repair or Replace: How to Decide · Furnace Rollout Codes and Carbon Monoxide Safety · Furnace Short Cycling: Causes and What to Check · How to Read a Bryant Furnace LED Code · How to Read a Furnace LED Flash Code · How to Reset a Gas Furnace Safely · Why Is My Furnace Blinking a Code?. All guides.

Brands

Codes we cover

EE0Amana · furnace

Furnace lockout after an excessive number of ignition retries (3 total): flame was not established, or flame was lost after it was established.

EE2Amana · furnace

Low stage pressure switch circuit is not closed.

EE3Amana · furnace

Primary limit circuit is open. The chart lists insufficient air over the heat exchanger.

EE4Amana · furnace

Flame was sensed with no call for heat.

EE6Amana · furnace

Flame sense microamp signal is low.

EE7Amana · furnace

Igniter circuit fault. The furnace fails to operate.

EE8Amana · furnace

High stage pressure switch circuit is closed at the start of the heating cycle.

EE9Amana · furnace

High stage pressure switch circuit is not closed.

EE5Amana · furnace

Open fuse, with no furnace operation.

EEFAmana · furnace

Auxiliary limit switch (condensate switch) is open. The furnace fails to operate.

EEdAmana · furnace

Auxiliary limit switch in the blower compartment is open. The furnace fails to operate.

E04American Standard · furnace

Open limit: the main thermal limit, a rollout switch, or the reverse airflow switch.

E05American Standard · furnace

Flame was detected when it should not be present.

E09American Standard · furnace

Open inducer limit switch, or open condensate pressure switch.

E12American Standard · furnace

Open fuse. The control diagram in this installer's guide labels the low-voltage fuse as 5 amp.

E08American Standard · furnace

Flame current is low, but still strong enough to allow operation.

E2.1American Standard · furnace

Retry exceeded: flame was never sensed. One-hour lockout after 3 times.

E2.2American Standard · furnace

Recycles exceeded: flame was sensed and then lost. One-hour lockout after 10 times.

E3.1American Standard · furnace

Shorted pressure switch, 1st stage.

E2.3American Standard · furnace

1st stage gas valve was not energized when it should be, and that fault was exceeded after 10 times.

E3.4American Standard · furnace

Open pressure switch, 2nd stage.

E6.3American Standard · furnace

Igniter fault: the igniter relay fails, or the igniter is open.

E3.2American Standard · furnace

Open pressure switch, 1st stage.

E7.1American Standard · furnace

The 1st stage gas valve (MVL) is energized when it should be off.

12Bryant · furnace

Blower on after power-up. The blower runs for 90 seconds if the furnace is powered up during a call for heat, or if that call opens during the blower on-delay. The same guide's sequence says the amber LED flashes 12 during those 90 seconds, then stays on continuously if no fault is found.

13Bryant · furnace

Limit circuit lockout. The limit or flame rollout switch was open longer than 3 minutes, or 10 successive limit trips occurred during high heat. The control auto-resets after 3 hours. The manual says to see status code 33.

14Bryant · furnace

Ignition lockout. The system failed to ignite gas and prove flame in 4 attempts. The control auto-resets after 3 hours. The manual says to see status code 34.

15Bryant · furnace

Blower motor lockout. The blower failed to reach 250 RPM, or failed to communicate, within 30 seconds after being turned on, in two successive heating cycles. The control auto-resets after 3 hours. The chart says to see status code 41.

21Bryant · furnace

Gas heating lockout. The control will not auto-reset. The chart says to check for a mis-wired gas valve or a defective control valve relay.

22Bryant · furnace

Abnormal flame-proving signal. Flame is proved while the gas valve is de-energized. The inducer runs until the fault clears. The chart says to check for a leaky gas valve or a stuck-open gas valve.

23Bryant · furnace

Pressure switch did not open. The chart says to check for obstructed pressure tubing or a pressure switch stuck closed.

24Bryant · furnace

Secondary voltage fuse is open. The chart says to check for a short circuit in the secondary (24 V) wiring.

25Bryant · furnace

Model selection or setup error. The model plug PL4 is missing or incorrect, or setup switch SW1-1 or SW1-6 is in the wrong position. If 25 flashes only four times at power-up, the control is using the model stored in memory.

31Bryant · furnace

High-heat pressure switch or relay did not close, or it reopened. The chart says the control relay may be defective or the gas valve may be mis-wired, and it says to see status code 32.

32Bryant · furnace

Low-heat pressure switch did not close, or it reopened. If it stays open longer than five minutes, the inducer shuts off for 15 minutes before a retry. If it opens during the blower on-delay, the blower comes on for the selected blower off-delay.

33Bryant · furnace

Limit circuit fault. A limit, draft safeguard, flame rollout, or blocked-vent switch is open, or the furnace is in high-heat only after two successive low-heat limit trips. The blower runs for 4 minutes or until the switch remakes, whichever is longer. Open longer than 3 minutes becomes lockout 13.

34Bryant · furnace

Ignition proving failure. The control tries three more times before lockout 14. If the flame signal is lost during the blower on-delay, the blower runs the selected off-delay.

35Bryant · furnace

Gas valve fault on a Bryant 987MA modulating furnace. The modulating gas valve failed to respond to a command from the furnace control, or power to the gas valve electronics was interrupted.

41Bryant · furnace

Blower motor fault. The blower failed to reach 250 RPM, or failed to communicate, within 30 seconds after being turned on or within 10 seconds during steady-state operation.

42Bryant · furnace

Inducer motor fault on a Bryant 987MA modulating furnace. The inducer has not started within 20 seconds after a call for heat, the inducer RPM is outside its valid range, or the RPM signal was lost for 5 seconds during operation.

43Bryant · furnace

Low-heat pressure switch is open while the high-heat pressure switch is closed. The chart says to check the pressure tubing, low inlet gas pressure if a low-gas-pressure switch is used, mis-wired switches, and a low-heat switch stuck open.

rapid flashingBryant · furnace

Line voltage polarity is reversed, or, on twinned furnaces, the transformers are out of phase. The status table states the polarity fault. The rapid-flashing section is the twinning case.

45Bryant · furnace

Control circuitry lockout. The control auto-resets after a 1-hour lockout caused by a flame-sense circuit failure, a gas-valve relay stuck open, or a software check error. Reset power to clear the lockout. Replace the control if the code repeats.

11Carrier · furnace

No previous code. The service label says stored status codes are erased automatically after 72 hours.

12Carrier · furnace

Blower on after power-up. The service label calls this normal operation. The blower runs for 90 seconds if the furnace was powered up during a call for heat, or if that call opened during the blower on-delay.

13Carrier · furnace

Limit circuit lockout: a limit or flame rollout switch was open longer than 3 minutes. Control auto-resets after 3 hours (see code 33).

21Carrier · furnace

Gas heating lockout. Control will NOT auto-reset.

14Carrier · furnace

Ignition lockout: system failed to ignite gas and prove flame in 4 attempts. Control auto-resets after 3 hours (see code 34).

22Carrier · furnace

Abnormal flame-proving signal: flame is proved while the gas valve is de-energized. Inducer runs until the fault is cleared.

23Carrier · furnace

Pressure switch did not open.

24Carrier · furnace

Secondary voltage (24 V) fuse is open.

31Carrier · furnace

Low (LPS) or high (HPS) pressure switch did not close or reopened.

33Carrier · furnace

Limit circuit fault: a limit or flame rollout switch is open. Becomes lockout 13 if open longer than 3 minutes.

34Carrier · furnace

Ignition proving failure: flame not sensed during trial for ignition. Control tries 3 more times before lockout 14.

45Carrier · furnace

Control circuitry lockout. Auto-resets after 1 hour.

Continuous onCarrier · furnace

Control has 24 VAC power: a steady amber LED is not a fault code.

Rapid flashingCarrier · furnace

Line voltage (115 VAC) polarity reversed. If twinned, check 24 V transformer phasing.

Continuous offCarrier · furnace

Status LED stays off: the service label says to check for 115 VAC at L1 and L2, and for 24 VAC at SEC-1 and SEC-2.

E10Goodman · furnace

Grounding fault / poor neutral connection.

E11Goodman · furnace

Open rollout switch.

EAFGoodman · furnace

Lost communication with the R-32 sensor: heating stops and only the fan runs because the furnace is in mitigation mode.

EALGoodman · furnace

R-32 sensor reports a refrigerant leak: heating stops and only the fan runs while the furnace is in mitigation mode. The chart says normal operation returns once a leak is not detected and the 5-minute delay is over.

EASGoodman · furnace

R-32 sensor fault: heating stops and only the fan runs while the furnace is in mitigation mode.

EbLGoodman · furnace

Blower current too low after the heat on-delay: the main blower is below the value the control expected, and the furnace goes to hard lockout.

EarGoodman · furnace

A2L relay fault: heating stops and only the fan runs while the furnace is in mitigation mode. The fault is on the furnace control board.

EbUGoodman · furnace

Blower current too high during pre-purge: the main blower is above the value the control expected, and the furnace goes to hard lockout.

EE0Goodman · furnace

Furnace lockout after too many ignition retries (3 total): flame failed to establish or was lost after establishment.

EE1Goodman · furnace

Pressure switch circuit is closed at the start of the heating cycle.

EE2Goodman · furnace

Pressure switch circuit is not closed.

EE3Goodman · furnace

Primary limit circuit is open.

EE5Goodman · furnace

Open fuse.

EE4Goodman · furnace

Flame sensed with no call for heat.

EE6Goodman · furnace

Low flame signal: flame sense microamp signal is minimal.

EEAGoodman · furnace

Polarity of 115 volt AC is reversed, or poor unit ground.

EEbGoodman · furnace

Gas valve is not energized when it should be.

EECGoodman · furnace

Gas valve is energized when it should not be.

EEEGoodman · furnace

Internal faults or IRQ loss in control board.

EEHGoodman · furnace

Twin error. The twinning feature is not working. The chart says to check the wiring connections, then replace the integrated control board.

EEJGoodman · furnace

Inducer relay error. The furnace fails to operate, and the chart says to replace the integrated control board.

EELGoodman · furnace

Problem with igniter circuit.

EEnGoodman · furnace

Igniter open.

Alternating fast flashLennox · furnace

Improper main ground, OR line voltage below 90 volts. Control will not respond to a heat call until voltage rises above 95 volts.

Alternating slow flashLennox · furnace

Watchguard 1 hour: burners failed to ignite or lost flame 5 times during a single heating demand.

Board failure patternLennox · furnace

Circuit board failure or control wired incorrectly.

E200Lennox · furnace

Hard lockout: the rollout circuit is open, or it was open.

E223Lennox · furnace

Low pressure switch failed open.

E250Lennox · furnace

Limit switch circuit open. If the limit does not close within 3 minutes, the furnace goes into a 1-hour soft lockout.

E270Lennox · furnace

Soft lockout: retries ran out and no flame current was sensed.

E291Lennox · furnace

Restricted heat airflow: airflow is below the minimum, and the furnace is in a 1-hour soft lockout.

Red off, green slow flashLennox · furnace

Pressure prove switch open, OR blocked inlet/exhaust vent, OR pressure switch closed before the combustion air inducer started.

Red fast flash, green slow flashLennox · furnace

Main power polarity reversed. Switch line and neutral.

Red on, green slow flashLennox · furnace

Rollout switch open, OR 12-pin connector improperly attached.

Red slow flash, green offLennox · furnace

Flame sensed without gas valve energized.

Red slow flash, green onLennox · furnace

Primary or secondary limit switch open. Limit must close within 3 minutes or the unit goes into 1-hour Watchguard.

Red slow flash, green fast flashLennox · furnace

Low flame signal: measures below 1.5 microamps. Replace flame sense rod.

10Rheem · furnace

One-hour lockout, caused by repeated failed ignition (11), water sensed (59), dead blower (61), internal fault (93), flame lost 5 times (13) or unexpected flame (14).

11Rheem · furnace

Failed ignition. After four failed attempts the control enters one-hour lockout (10).

12Rheem · furnace

Low flame sense: flame sense current is weak or marginal. Furnace keeps running.

13Rheem · furnace

Flame lost after established.

14Rheem · furnace

Flame present with gas valve off. Extremely critical; furnace will not operate.

30Rheem · furnace

Open fuse, usually from a 24 VAC short to common or ground.

33Rheem · furnace

Over-temperature (rollout) switch open: flames rolled out of the heat exchanger into the burner compartment.

44Rheem · furnace

Low pressure switch closed with inducer off.

45Rheem · furnace

Low pressure switch open with inducer on high speed.

46Rheem · furnace

Low pressure switch open with inducer on low speed.

55Rheem · furnace

High pressure switch closed while the inducer is off. This is a critical fault for gas heat. Cooling can still run. The code is present during a heat call before pre-purge.

58Rheem · furnace

Water circuit open. The control cannot see continuity between pins 1 and 2 of connector P4, so it does not see both water sensors. Gas heat will not run. Other modes, such as cooling, should.

57Rheem · furnace

High pressure switch open with inducer on high speed; furnace may drop to low fire.

59Rheem · furnace

Water sensed in the collector box; gas heat will not run.

60Rheem · furnace

Blower fault, blower can still run: blower at max speed/torque or temperature limit because static pressure is too high.

61Rheem · furnace

Blower fault, motor cannot run. Furnace will not operate in any mode.

d4Rheem · furnace

No valid model data on the memory card. This is a non-critical fault. The furnace should still operate, and d4 is displayed in standby.

d1Rheem · furnace

No model data. This is a critical fault. The furnace will not operate in any mode, including a thermostat call.

d6Rheem · furnace

Horsepower conflict on the memory card. The motor's horsepower does not match the card, but the model data in the furnace control does match the motor. This is a non-critical fault, shown in standby.

E01Trane · furnace

Loss of the IRQ or other internal failures (internal furnace control error).

E04Trane · furnace

Open limit: main thermal limit, flame rollout switch, or reverse airflow switch.

E05Trane · furnace

Flame detected when it should not be present.

E06Trane · furnace

Voltage reversed polarity or bad grounding.

E08Trane · furnace

Low flame current, but still strong enough to allow operation.

E09Trane · furnace

Open inducer limit switch or condensate pressure switch.

E10Trane · furnace

Inducer and blower are not communicating: the service facts call this an internal control-board error between those two microprocessors.

E11Trane · furnace

Gas-valve relay fault, or 24 VAC at the 2nd stage valve: the control reports failed internal gas-valve relays, or voltage sensed at the 2nd stage gas valve.

E12Trane · furnace

Open fuse: the onboard 5 amp fuse is open or missing.

E13Trane · furnace

Blower does not match the personality module: the motor horsepower or OEM identification differs from the value programmed on the module.

E15Trane · furnace

Personality module and control data are both corrupted.

E14Trane · furnace

Personality module missing: the control cannot read the information stored on the board.

E17Trane · furnace

No return signal from the blower: the integrated furnace control does not see the motor answer.

E18Trane · furnace

Control does not see its own send message: the integrated furnace control is not seeing the blower-communication send.

E2.1Trane · furnace

Retry exceeded: flame never sensed after 3 ignition tries in one call for heat. One-hour lockout.

E2.3Trane · furnace

1st stage gas valve not energized: it failed 10 times in the same call for heat. The service facts say 24 VAC was not sensed on MVL those 10 times.

E2.4Trane · furnace

High-limit output relay is not closed when it should be. The service facts say 24 VAC was not sensed on HLO ten times.

E3.1Trane · furnace

Shorted pressure switch, 1st stage: PS1 is closed when it should be open.

E2.2Trane · furnace

Recycles exceeded: flame sensed then lost 10 times (or PS1 open 10 times) in one call for heat. One-hour lockout.

E3.2Trane · furnace

Open pressure switch, 1st stage: PS1 is open when it should be closed.

E3.3Trane · furnace

2nd stage pressure switch PS2 is closed when it should be open. The service facts say the pressure switch is not the problem in most cases.

E3.4Trane · furnace

Open pressure switch, 2nd stage: PS2 is open when it should be closed.

E6.3Trane · furnace

Igniter relay fault or igniter open/shorted.

E7.1Trane · furnace

1st stage gas valve (MVL) is energized when it should be off.

E7.2Trane · furnace

Redundant high-limit relay stuck closed: the service facts call this an internal control-board error. The relay is closed when it should not be.

1 red flashYork · furnace

Flame was sensed when there was not a call for heat. The control turns on both the inducer motor and the supply air blower.

11 red flashesYork · furnace

The main limit switch has opened and stayed open for more than five minutes. The manual says this is usually a failed blower motor or blower wheel. The control is in a hard lockout. Power has to be cycled off and on only after the problem is corrected.

10 red flashesYork · furnace

The gas valve is energized with no call for heat. The main blower and the inducer blower run, and no ignition sequence starts, for as long as this condition exists.

2 red flashesYork · furnace

The pressure switch is closed when it should be open. The control checks that the contacts are open at the start of each heat cycle and will not continue ignition if they are already closed.

4 red flashesYork · furnace

The main limit switch has opened its normally closed contacts. The control runs the supply air blower and the inducer while the limit stays open.

3 red flashesYork · furnace

The pressure switch contacts are open when they should be closed.

7 red flashesYork · furnace

The flame could not be established during three trials for ignition. The furnace locks out for one hour and then restarts.

6 red flashesYork · furnace

While the furnace was operating, the pressure switch opened four times during the call for heat. The furnace locks out for one hour and then restarts.

8 red flashesYork · furnace

The flame was lost five times (four recycles) during the heating cycle. The furnace locks out for one hour and then restarts.

5 red flashesYork · furnace

The normally closed rollout switch has opened. The rollout control is manually reset. The control enters a hard lockout, and power has to be cycled off and on only after the problem is corrected.

9 red flashesYork · furnace

Reversed line-voltage polarity, a grounding problem, or reversed low-voltage transformer wires. Heating and cooling are both affected. The furnace will not start the ignition sequence until this is corrected.

continuous amberYork · furnace

Flame sense current is below 1.5 microamps. The manual's ignition-control levels put a normal flame sense current at about 3.7 microamps DC, the low-flame warning at 1.5 microamps, and the control lockout point at 0.1 microamps DC.

Parts and tools for furnace codes · Every page links its source · Last updated · Search every category