Furnace error codes
What does your furnace error code mean? These are the gas furnace flash codes and display codes from Goodman, Trane, Rheem, Carrier and Lennox manuals. Pick your brand to see what a code means, how to fix it safely and when to call a pro.
The boards do not share one code language. On the Carrier 59SC5, status codes are short and long flashes of one LED: code 33 is three short and three long, and it means a limit or flame rollout switch is open. Goodman GR9S96 and GD9S96 show two characters on a 7-segment display, so EE3 is an open primary limit and E11 is an open rollout switch. Lennox ML180UH uses a red LED and a green LED together. Rheem R96V and Trane S9V2 use 7-segment displays (Rheem 33 is an open rollout switch; Trane E04 is an open limit, rollout or reverse-airflow switch). Read the pattern before you cut power. Several of these manuals also store a fault history, which a reset can clear. The longer explanations are in the furnace guides: how to read the light, how a reset works, what a pressure-switch code is asking the draft system to prove, and when a rollout or limit code is a reason to stop and call a technician rather than try another cycle. The winter 2026 no-heat checklist follows those same documents for a furnace that will not heat. The part finder lists a part only when one of these manuals names it on that code. Lennox SL280DFNV is a different display from the ML180 red-and-green chart: a seven-segment LED. E200 is a rollout hard lockout. E223 is the low pressure switch failed open. E250 is the limit circuit open. E270 is a soft lockout after retries with no flame current. E291 is heat airflow below the minimum, and that row names a dirty filter.
Guides for this equipment: Furnace Air Filters: How Often to Change and Why It Matters · Furnace Blowing Cold Air: Common Causes · Furnace Flame Sensor: Symptoms, Codes and Cleaning · Furnace Ignition Lockout: It Tried to Light and Stopped · Furnace Limit Switch Open: Blower Runs, No Heat · Furnace No Heat: Winter 2026 Checklist · Furnace Pressure Switch Error: What It Means · Furnace Repair or Replace: How to Decide · Furnace Rollout Codes and Carbon Monoxide Safety · Furnace Short Cycling: Causes and What to Check · How to Read a Bryant Furnace LED Code · How to Read a Furnace LED Flash Code · How to Reset a Gas Furnace Safely · Why Is My Furnace Blinking a Code?. All guides.
Brands
Codes we cover
Furnace lockout after an excessive number of ignition retries (3 total): flame was not established, or flame was lost after it was established.
EE2Amana · furnaceLow stage pressure switch circuit is not closed.
EE3Amana · furnacePrimary limit circuit is open. The chart lists insufficient air over the heat exchanger.
EE4Amana · furnaceFlame was sensed with no call for heat.
EE6Amana · furnaceFlame sense microamp signal is low.
EE7Amana · furnaceIgniter circuit fault. The furnace fails to operate.
EE8Amana · furnaceHigh stage pressure switch circuit is closed at the start of the heating cycle.
EE9Amana · furnaceHigh stage pressure switch circuit is not closed.
EE5Amana · furnaceOpen fuse, with no furnace operation.
EEFAmana · furnaceAuxiliary limit switch (condensate switch) is open. The furnace fails to operate.
EEdAmana · furnaceAuxiliary limit switch in the blower compartment is open. The furnace fails to operate.
E04American Standard · furnaceOpen limit: the main thermal limit, a rollout switch, or the reverse airflow switch.
E05American Standard · furnaceFlame was detected when it should not be present.
E09American Standard · furnaceOpen inducer limit switch, or open condensate pressure switch.
E12American Standard · furnaceOpen fuse. The control diagram in this installer's guide labels the low-voltage fuse as 5 amp.
E08American Standard · furnaceFlame current is low, but still strong enough to allow operation.
E2.1American Standard · furnaceRetry exceeded: flame was never sensed. One-hour lockout after 3 times.
E2.2American Standard · furnaceRecycles exceeded: flame was sensed and then lost. One-hour lockout after 10 times.
E3.1American Standard · furnaceShorted pressure switch, 1st stage.
E2.3American Standard · furnace1st stage gas valve was not energized when it should be, and that fault was exceeded after 10 times.
E3.4American Standard · furnaceOpen pressure switch, 2nd stage.
E6.3American Standard · furnaceIgniter fault: the igniter relay fails, or the igniter is open.
E3.2American Standard · furnaceOpen pressure switch, 1st stage.
E7.1American Standard · furnaceThe 1st stage gas valve (MVL) is energized when it should be off.
12Bryant · furnaceBlower on after power-up. The blower runs for 90 seconds if the furnace is powered up during a call for heat, or if that call opens during the blower on-delay. The same guide's sequence says the amber LED flashes 12 during those 90 seconds, then stays on continuously if no fault is found.
13Bryant · furnaceLimit circuit lockout. The limit or flame rollout switch was open longer than 3 minutes, or 10 successive limit trips occurred during high heat. The control auto-resets after 3 hours. The manual says to see status code 33.
14Bryant · furnaceIgnition lockout. The system failed to ignite gas and prove flame in 4 attempts. The control auto-resets after 3 hours. The manual says to see status code 34.
15Bryant · furnaceBlower motor lockout. The blower failed to reach 250 RPM, or failed to communicate, within 30 seconds after being turned on, in two successive heating cycles. The control auto-resets after 3 hours. The chart says to see status code 41.
21Bryant · furnaceGas heating lockout. The control will not auto-reset. The chart says to check for a mis-wired gas valve or a defective control valve relay.
22Bryant · furnaceAbnormal flame-proving signal. Flame is proved while the gas valve is de-energized. The inducer runs until the fault clears. The chart says to check for a leaky gas valve or a stuck-open gas valve.
23Bryant · furnacePressure switch did not open. The chart says to check for obstructed pressure tubing or a pressure switch stuck closed.
24Bryant · furnaceSecondary voltage fuse is open. The chart says to check for a short circuit in the secondary (24 V) wiring.
25Bryant · furnaceModel selection or setup error. The model plug PL4 is missing or incorrect, or setup switch SW1-1 or SW1-6 is in the wrong position. If 25 flashes only four times at power-up, the control is using the model stored in memory.
31Bryant · furnaceHigh-heat pressure switch or relay did not close, or it reopened. The chart says the control relay may be defective or the gas valve may be mis-wired, and it says to see status code 32.
32Bryant · furnaceLow-heat pressure switch did not close, or it reopened. If it stays open longer than five minutes, the inducer shuts off for 15 minutes before a retry. If it opens during the blower on-delay, the blower comes on for the selected blower off-delay.
33Bryant · furnaceLimit circuit fault. A limit, draft safeguard, flame rollout, or blocked-vent switch is open, or the furnace is in high-heat only after two successive low-heat limit trips. The blower runs for 4 minutes or until the switch remakes, whichever is longer. Open longer than 3 minutes becomes lockout 13.
34Bryant · furnaceIgnition proving failure. The control tries three more times before lockout 14. If the flame signal is lost during the blower on-delay, the blower runs the selected off-delay.
35Bryant · furnaceGas valve fault on a Bryant 987MA modulating furnace. The modulating gas valve failed to respond to a command from the furnace control, or power to the gas valve electronics was interrupted.
41Bryant · furnaceBlower motor fault. The blower failed to reach 250 RPM, or failed to communicate, within 30 seconds after being turned on or within 10 seconds during steady-state operation.
42Bryant · furnaceInducer motor fault on a Bryant 987MA modulating furnace. The inducer has not started within 20 seconds after a call for heat, the inducer RPM is outside its valid range, or the RPM signal was lost for 5 seconds during operation.
43Bryant · furnaceLow-heat pressure switch is open while the high-heat pressure switch is closed. The chart says to check the pressure tubing, low inlet gas pressure if a low-gas-pressure switch is used, mis-wired switches, and a low-heat switch stuck open.
rapid flashingBryant · furnaceLine voltage polarity is reversed, or, on twinned furnaces, the transformers are out of phase. The status table states the polarity fault. The rapid-flashing section is the twinning case.
45Bryant · furnaceControl circuitry lockout. The control auto-resets after a 1-hour lockout caused by a flame-sense circuit failure, a gas-valve relay stuck open, or a software check error. Reset power to clear the lockout. Replace the control if the code repeats.
11Carrier · furnaceNo previous code. The service label says stored status codes are erased automatically after 72 hours.
12Carrier · furnaceBlower on after power-up. The service label calls this normal operation. The blower runs for 90 seconds if the furnace was powered up during a call for heat, or if that call opened during the blower on-delay.
13Carrier · furnaceLimit circuit lockout: a limit or flame rollout switch was open longer than 3 minutes. Control auto-resets after 3 hours (see code 33).
21Carrier · furnaceGas heating lockout. Control will NOT auto-reset.
14Carrier · furnaceIgnition lockout: system failed to ignite gas and prove flame in 4 attempts. Control auto-resets after 3 hours (see code 34).
22Carrier · furnaceAbnormal flame-proving signal: flame is proved while the gas valve is de-energized. Inducer runs until the fault is cleared.
23Carrier · furnacePressure switch did not open.
24Carrier · furnaceSecondary voltage (24 V) fuse is open.
31Carrier · furnaceLow (LPS) or high (HPS) pressure switch did not close or reopened.
33Carrier · furnaceLimit circuit fault: a limit or flame rollout switch is open. Becomes lockout 13 if open longer than 3 minutes.
34Carrier · furnaceIgnition proving failure: flame not sensed during trial for ignition. Control tries 3 more times before lockout 14.
45Carrier · furnaceControl circuitry lockout. Auto-resets after 1 hour.
Continuous onCarrier · furnaceControl has 24 VAC power: a steady amber LED is not a fault code.
Rapid flashingCarrier · furnaceLine voltage (115 VAC) polarity reversed. If twinned, check 24 V transformer phasing.
Continuous offCarrier · furnaceStatus LED stays off: the service label says to check for 115 VAC at L1 and L2, and for 24 VAC at SEC-1 and SEC-2.
E10Goodman · furnaceGrounding fault / poor neutral connection.
E11Goodman · furnaceOpen rollout switch.
EAFGoodman · furnaceLost communication with the R-32 sensor: heating stops and only the fan runs because the furnace is in mitigation mode.
EALGoodman · furnaceR-32 sensor reports a refrigerant leak: heating stops and only the fan runs while the furnace is in mitigation mode. The chart says normal operation returns once a leak is not detected and the 5-minute delay is over.
EASGoodman · furnaceR-32 sensor fault: heating stops and only the fan runs while the furnace is in mitigation mode.
EbLGoodman · furnaceBlower current too low after the heat on-delay: the main blower is below the value the control expected, and the furnace goes to hard lockout.
EarGoodman · furnaceA2L relay fault: heating stops and only the fan runs while the furnace is in mitigation mode. The fault is on the furnace control board.
EbUGoodman · furnaceBlower current too high during pre-purge: the main blower is above the value the control expected, and the furnace goes to hard lockout.
EE0Goodman · furnaceFurnace lockout after too many ignition retries (3 total): flame failed to establish or was lost after establishment.
EE1Goodman · furnacePressure switch circuit is closed at the start of the heating cycle.
EE2Goodman · furnacePressure switch circuit is not closed.
EE3Goodman · furnacePrimary limit circuit is open.
EE5Goodman · furnaceOpen fuse.
EE4Goodman · furnaceFlame sensed with no call for heat.
EE6Goodman · furnaceLow flame signal: flame sense microamp signal is minimal.
EEAGoodman · furnacePolarity of 115 volt AC is reversed, or poor unit ground.
EEbGoodman · furnaceGas valve is not energized when it should be.
EECGoodman · furnaceGas valve is energized when it should not be.
EEEGoodman · furnaceInternal faults or IRQ loss in control board.
EEHGoodman · furnaceTwin error. The twinning feature is not working. The chart says to check the wiring connections, then replace the integrated control board.
EEJGoodman · furnaceInducer relay error. The furnace fails to operate, and the chart says to replace the integrated control board.
EELGoodman · furnaceProblem with igniter circuit.
EEnGoodman · furnaceIgniter open.
Alternating fast flashLennox · furnaceImproper main ground, OR line voltage below 90 volts. Control will not respond to a heat call until voltage rises above 95 volts.
Alternating slow flashLennox · furnaceWatchguard 1 hour: burners failed to ignite or lost flame 5 times during a single heating demand.
Board failure patternLennox · furnaceCircuit board failure or control wired incorrectly.
E200Lennox · furnaceHard lockout: the rollout circuit is open, or it was open.
E223Lennox · furnaceLow pressure switch failed open.
E250Lennox · furnaceLimit switch circuit open. If the limit does not close within 3 minutes, the furnace goes into a 1-hour soft lockout.
E270Lennox · furnaceSoft lockout: retries ran out and no flame current was sensed.
E291Lennox · furnaceRestricted heat airflow: airflow is below the minimum, and the furnace is in a 1-hour soft lockout.
Red off, green slow flashLennox · furnacePressure prove switch open, OR blocked inlet/exhaust vent, OR pressure switch closed before the combustion air inducer started.
Red fast flash, green slow flashLennox · furnaceMain power polarity reversed. Switch line and neutral.
Red on, green slow flashLennox · furnaceRollout switch open, OR 12-pin connector improperly attached.
Red slow flash, green offLennox · furnaceFlame sensed without gas valve energized.
Red slow flash, green onLennox · furnacePrimary or secondary limit switch open. Limit must close within 3 minutes or the unit goes into 1-hour Watchguard.
Red slow flash, green fast flashLennox · furnaceLow flame signal: measures below 1.5 microamps. Replace flame sense rod.
10Rheem · furnaceOne-hour lockout, caused by repeated failed ignition (11), water sensed (59), dead blower (61), internal fault (93), flame lost 5 times (13) or unexpected flame (14).
11Rheem · furnaceFailed ignition. After four failed attempts the control enters one-hour lockout (10).
12Rheem · furnaceLow flame sense: flame sense current is weak or marginal. Furnace keeps running.
13Rheem · furnaceFlame lost after established.
14Rheem · furnaceFlame present with gas valve off. Extremely critical; furnace will not operate.
30Rheem · furnaceOpen fuse, usually from a 24 VAC short to common or ground.
33Rheem · furnaceOver-temperature (rollout) switch open: flames rolled out of the heat exchanger into the burner compartment.
44Rheem · furnaceLow pressure switch closed with inducer off.
45Rheem · furnaceLow pressure switch open with inducer on high speed.
46Rheem · furnaceLow pressure switch open with inducer on low speed.
55Rheem · furnaceHigh pressure switch closed while the inducer is off. This is a critical fault for gas heat. Cooling can still run. The code is present during a heat call before pre-purge.
58Rheem · furnaceWater circuit open. The control cannot see continuity between pins 1 and 2 of connector P4, so it does not see both water sensors. Gas heat will not run. Other modes, such as cooling, should.
57Rheem · furnaceHigh pressure switch open with inducer on high speed; furnace may drop to low fire.
59Rheem · furnaceWater sensed in the collector box; gas heat will not run.
60Rheem · furnaceBlower fault, blower can still run: blower at max speed/torque or temperature limit because static pressure is too high.
61Rheem · furnaceBlower fault, motor cannot run. Furnace will not operate in any mode.
d4Rheem · furnaceNo valid model data on the memory card. This is a non-critical fault. The furnace should still operate, and d4 is displayed in standby.
d1Rheem · furnaceNo model data. This is a critical fault. The furnace will not operate in any mode, including a thermostat call.
d6Rheem · furnaceHorsepower conflict on the memory card. The motor's horsepower does not match the card, but the model data in the furnace control does match the motor. This is a non-critical fault, shown in standby.
E01Trane · furnaceLoss of the IRQ or other internal failures (internal furnace control error).
E04Trane · furnaceOpen limit: main thermal limit, flame rollout switch, or reverse airflow switch.
E05Trane · furnaceFlame detected when it should not be present.
E06Trane · furnaceVoltage reversed polarity or bad grounding.
E08Trane · furnaceLow flame current, but still strong enough to allow operation.
E09Trane · furnaceOpen inducer limit switch or condensate pressure switch.
E10Trane · furnaceInducer and blower are not communicating: the service facts call this an internal control-board error between those two microprocessors.
E11Trane · furnaceGas-valve relay fault, or 24 VAC at the 2nd stage valve: the control reports failed internal gas-valve relays, or voltage sensed at the 2nd stage gas valve.
E12Trane · furnaceOpen fuse: the onboard 5 amp fuse is open or missing.
E13Trane · furnaceBlower does not match the personality module: the motor horsepower or OEM identification differs from the value programmed on the module.
E15Trane · furnacePersonality module and control data are both corrupted.
E14Trane · furnacePersonality module missing: the control cannot read the information stored on the board.
E17Trane · furnaceNo return signal from the blower: the integrated furnace control does not see the motor answer.
E18Trane · furnaceControl does not see its own send message: the integrated furnace control is not seeing the blower-communication send.
E2.1Trane · furnaceRetry exceeded: flame never sensed after 3 ignition tries in one call for heat. One-hour lockout.
E2.3Trane · furnace1st stage gas valve not energized: it failed 10 times in the same call for heat. The service facts say 24 VAC was not sensed on MVL those 10 times.
E2.4Trane · furnaceHigh-limit output relay is not closed when it should be. The service facts say 24 VAC was not sensed on HLO ten times.
E3.1Trane · furnaceShorted pressure switch, 1st stage: PS1 is closed when it should be open.
E2.2Trane · furnaceRecycles exceeded: flame sensed then lost 10 times (or PS1 open 10 times) in one call for heat. One-hour lockout.
E3.2Trane · furnaceOpen pressure switch, 1st stage: PS1 is open when it should be closed.
E3.3Trane · furnace2nd stage pressure switch PS2 is closed when it should be open. The service facts say the pressure switch is not the problem in most cases.
E3.4Trane · furnaceOpen pressure switch, 2nd stage: PS2 is open when it should be closed.
E6.3Trane · furnaceIgniter relay fault or igniter open/shorted.
E7.1Trane · furnace1st stage gas valve (MVL) is energized when it should be off.
E7.2Trane · furnaceRedundant high-limit relay stuck closed: the service facts call this an internal control-board error. The relay is closed when it should not be.
1 red flashYork · furnaceFlame was sensed when there was not a call for heat. The control turns on both the inducer motor and the supply air blower.
11 red flashesYork · furnaceThe main limit switch has opened and stayed open for more than five minutes. The manual says this is usually a failed blower motor or blower wheel. The control is in a hard lockout. Power has to be cycled off and on only after the problem is corrected.
10 red flashesYork · furnaceThe gas valve is energized with no call for heat. The main blower and the inducer blower run, and no ignition sequence starts, for as long as this condition exists.
2 red flashesYork · furnaceThe pressure switch is closed when it should be open. The control checks that the contacts are open at the start of each heat cycle and will not continue ignition if they are already closed.
4 red flashesYork · furnaceThe main limit switch has opened its normally closed contacts. The control runs the supply air blower and the inducer while the limit stays open.
3 red flashesYork · furnaceThe pressure switch contacts are open when they should be closed.
7 red flashesYork · furnaceThe flame could not be established during three trials for ignition. The furnace locks out for one hour and then restarts.
6 red flashesYork · furnaceWhile the furnace was operating, the pressure switch opened four times during the call for heat. The furnace locks out for one hour and then restarts.
8 red flashesYork · furnaceThe flame was lost five times (four recycles) during the heating cycle. The furnace locks out for one hour and then restarts.
5 red flashesYork · furnaceThe normally closed rollout switch has opened. The rollout control is manually reset. The control enters a hard lockout, and power has to be cycled off and on only after the problem is corrected.
9 red flashesYork · furnaceReversed line-voltage polarity, a grounding problem, or reversed low-voltage transformer wires. Heating and cooling are both affected. The furnace will not start the ignition sequence until this is corrected.
continuous amberYork · furnaceFlame sense current is below 1.5 microamps. The manual's ignition-control levels put a normal flame sense current at about 3.7 microamps DC, the low-flame warning at 1.5 microamps, and the control lockout point at 0.1 microamps DC.