American Standard E09: Open inducer limit switch, or open condensate pressure switch

Source: American Standard manual (PDF) (opens in a new tab) ↗ · Updated

Status codeE09American Standard
What does American Standard E09 mean?

Open inducer limit switch, or open condensate pressure switch.

How it shows: 7-segment display on an American Standard S9V2 two-stage variable-speed furnace: E09

American Standard S9V2 E09 is an open inducer limit switch or an open condensate pressure switch. The heating sequence will not start the inducer until both are proved closed, so the burners never reach ignition. It is not E3.2, the 1st stage pressure switch that proves inducer draft. A frozen condensate line belongs in this technician check, not in a jumper.

Likely causes

  • Inducer limit switch open
  • Condensate pressure switch open

Safe checks for E09

  1. The heating sequence will not start the inducer until the condensate pressure switch and the inducer limit switch are proved closed
  2. Techniciancheck the inducer limit and the condensate pressure switch, including the condensate drain path those switches watch
Safety firstIf you smell gas, do not touch any electrical switch or use a phone in the building; leave immediately and call your gas supplier from outside. Turn off electrical power at the furnace switch or breaker before opening any panel, and never bypass or jumper a limit, rollout or pressure switch. Gas valve, burner, venting, wiring and control-board work should be done by a licensed HVAC technician.

Capacitors can hold a charge after the power is off. Safety terms.

When to call a pro

Call a licensed HVAC technician. E09 stops the heating cycle before ignition. A frozen or blocked condensate line is a technician diagnosis on this control.

Find a American Standard dealer (official locator, opens in a new tab) ↗

Email me this fix

We save your email and this page. Nothing is emailed. We'll only use your email for this request.

Privacy. Deletion requests go to the address on that page.

Request a filter and maintenance reminder

We save your email, this page, and the interval you pick. Nothing is emailed. We'll only use your email for this request.

Privacy. Deletion requests go to the address on that page.

Parts & tools for this fix

Taken from this code's causes or steps. A search link opens Amazon results and does not confirm a fit. Check the model number in the manual.

Furnace pressure switch hose: guide

Technician step in this code: check the inducer limit and the condensate pressure switch, including the condensate drain path those switches watch

See the guide for what to look for when buying one.

Furnace pressure switch: guide

In this code: Condensate pressure switch open

This one is for a technician to test or replace, so we only explain it and do not link to buy it.

Furnace inducer (draft) motor: guide

In this code: Inducer limit switch open

This one is for a technician to test or replace, so we only explain it and do not link to buy it.

High limit and rollout switches: guide

In this code: Inducer limit switch open

A safety device: we explain it but do not link to buy one.

Related American Standard codes

All American Standard codes →Browse every code