Code index · 16 entries

Carrier AC / heat pump error codes

Last updated

What does your Carrier AC / heat pump error code mean? 16 codes from official Carrier AC / heat pump documentation. Select a code for causes, how to fix it safely and when to call a pro. Carrier manufacturer manual (PDF) (opens in a new tab) ↗.

16 of these 16 Carrier AC / heat pump pages are marked call-a-pro because the source document points at gas, venting, refrigerant, high voltage or a control the manual does not leave to a homeowner. The other 0 start with a check the document describes, then say when to stop.

Related guides: AC High and Low Pressure Codes · AC Voltage and Power Codes: Brownout, L8, H8, E5 · Heat Pump Not Heating in the Cold · How to Read a Bryant Evolution Outdoor Status Light.

25AC / heat pump

Invalid model plug / inverter size: the control does not accept the model plug for this inverter.

Call a pro
31AC / heat pump

High pressure switch open: the unit steps down capacity for each occurrence and elevates to fault 84 if it happens on the lowest stage. Reset time is 6 minutes.

Call a pro
32AC / heat pump

Low pressure trip: the control elevates to fault 83 (low pressure lockout) after 3 occurrences. Reset time is 6 minutes.

Call a pro
33AC / heat pump

Lost inverter communications, the local fault. It is logged after 2 minutes with no communication between the outdoor control (AOC) and the inverter (MOC). It elevates to fault 48 after 3 consecutive failures within 20 minutes, or after 20 minutes of continuous loss of connection. The manual says to refer to fault code 48.

Call a pro
46AC / heat pump

Brownout event: low line voltage reaching the unit. Reset time is 6 minutes.

Call a pro
48AC / heat pump

Lost inverter communications (system malfunction): the outdoor control (AOC) and the inverter (MOC) have stopped communicating. Fault 33 is logged after 2 minutes with no communication and is elevated to 48 after 3 consecutive failures within 20 minutes, or 20 minutes of continuous loss of connection.

Call a pro
49AC / heat pump

Compressor overcurrent fault. The control elevates this to fault 95 after 5 occurrences. Reset time is 6 minutes.

Call a pro
53AC / heat pump

Outdoor air temperature sensor fault.

Call a pro
55AC / heat pump

Coil temperature sensor fault.

Call a pro
56AC / heat pump

Outdoor air temperature and outdoor coil temperature thermistors are out of range. The manual lists this as an event, not a lockout.

Call a pro
57AC / heat pump

Suction pressure sensor fault. The suction pressure transducer reading cannot be trusted. There is no reset time on this row.

Call a pro
65AC / heat pump

DC volts low, speed limiting. Supply voltage is under 197 V, or a loose wire or the inverter is limiting compressor speed. The table does not list a reset time.

Call a pro
83AC / heat pump

Low pressure lockout for 4 hours, elevated from fault 32 after 3 occurrences.

Call a pro
84AC / heat pump

High pressure lockout for 4 hours, elevated from fault 31 when the stage (speed) can no longer be lowered.

Call a pro
88AC / heat pump

Compressor and inverter lockout for 2 hours, elevated from fault 79 after 5 occurrences. The compressor failed to start often enough that the control stopped the retries.

Call a pro
95AC / heat pump

Compressor overcurrent lockout for 2 hours, elevated from fault 49 after 5 occurrences.

Call a pro

Parts and tools for Carrier AC / heat pump codes →

Source: Carrier manufacturer manual (PDF) (opens in a new tab) ↗ · Last updated

High voltageOutdoor units carry line voltage even when the thermostat is off. Switch off the disconnect and the breaker before opening any panel.