Carrier 49: Compressor overcurrent fault

Source: Carrier manual (PDF) (opens in a new tab) ↗ · Updated

Status code49Carrier
What does Carrier 49 mean?

Compressor overcurrent fault. The control elevates this to fault 95 after 5 occurrences. Reset time is 6 minutes.

Homeowner part this code names: AC coil cleaner.

Search on Amazon

Opens an Amazon search for that name. Check the size against your manual. As an Amazon Associate I earn from qualifying purchases.

Call a pro: jump to when to call a pro Equipment type: AC / heat pump
How it shows: Amber status LED on a Carrier Infinity 25VNA8 heat pump or 24VNA9 air conditioner. A short flash is 0.25 seconds on and a long flash is 1.0 second on. Code 49 is 4 short and 9 long

Carrier 49 is a compressor overcurrent fault, the local code. It elevates to fault 95 after 5 occurrences. Reset time is 6 minutes. Table 6 says to use the fault 95 checks. It is not brownout 46, and it is not the 2-hour lockout 95. Count 4 short flashes and 9 long flashes.

Likely causes

  • The service manual points code 49 at the fault 95 cause list
  • Compressor operating outside its allowed envelope, or high superheat
  • Incoming power supply voltage, loose power leads, or a phase imbalance
  • Outdoor airflow too low, refrigerant overcharge, inverter damage, or compressor internal damage

Safe checks for 49

  1. Count 4 short flashes and 9 long flashes. With power off, look at the outdoor coil for ice or debris. That is the airflow line on the fault 95 table this code points to
  2. Technicianfollow fault 95. Charge, winding resistance, voltage against the rating plate, and inverter or compressor replacement are that table
Safety firstOutdoor units carry line voltage even when the thermostat is off. Switch off the unit's disconnect and breaker before touching anything. Refrigerant, wiring, compressor and control-board work must be done by a licensed HVAC technician.

Capacitors can hold a charge after the power is off. Safety terms.

When to call a pro

Call a licensed HVAC technician if 49 repeats. Five occurrences become the 2-hour lockout 95.

Find a Carrier dealer (official locator, opens in a new tab) ↗

Email me this fix

We save your email and this page. Nothing is emailed. We'll only use your email for this request.

Privacy. Deletion requests go to the address on that page.

Request a filter and maintenance reminder

We save your email, this page, and the interval you pick. Nothing is emailed. We'll only use your email for this request.

Privacy. Deletion requests go to the address on that page.

Parts & tools for this fix

Taken from this code's causes or steps. A search link opens Amazon results and does not confirm a fit. Check the model number in the manual.

AC and heat pump coil cleaning supplies: guide

In this code: Count 4 short flashes and 9 long flashes. With power off, look at the outdoor coil for ice or debris. That is the airflow line on the fault 95 table this code points to

Multimeter for appliance and HVAC diagnosis: guide

In this code: Incoming power supply voltage, loose power leads, or a phase imbalance

This one is for a technician to test or replace, so we only explain it and do not link to buy it.

As an Amazon Associate I earn from qualifying purchases.Affiliate disclosure

Related Carrier AC / heat pump codes

All Carrier AC / heat pump codes →Browse every code