Compressor overcurrent fault. The control elevates this to fault 95 after 5 occurrences. Reset time is 6 minutes.
Homeowner part this code names: AC coil cleaner.
Search on AmazonOpens an Amazon search for that name. Check the size against your manual. As an Amazon Associate I earn from qualifying purchases.
Carrier 49 is a compressor overcurrent fault, the local code. It elevates to fault 95 after 5 occurrences. Reset time is 6 minutes. Table 6 says to use the fault 95 checks. It is not brownout 46, and it is not the 2-hour lockout 95. Count 4 short flashes and 9 long flashes.
Likely causes
- The service manual points code 49 at the fault 95 cause list
- Compressor operating outside its allowed envelope, or high superheat
- Incoming power supply voltage, loose power leads, or a phase imbalance
- Outdoor airflow too low, refrigerant overcharge, inverter damage, or compressor internal damage
Safe checks for 49
- Count 4 short flashes and 9 long flashes. With power off, look at the outdoor coil for ice or debris. That is the airflow line on the fault 95 table this code points to
- Technicianfollow fault 95. Charge, winding resistance, voltage against the rating plate, and inverter or compressor replacement are that table
Capacitors can hold a charge after the power is off. Safety terms.
When to call a pro
Call a licensed HVAC technician if 49 repeats. Five occurrences become the 2-hour lockout 95.
Find a Carrier dealer (official locator, opens in a new tab) ↗Email me this fix
We save your email and this page. Nothing is emailed. We'll only use your email for this request.
Request a filter and maintenance reminder
We save your email, this page, and the interval you pick. Nothing is emailed. We'll only use your email for this request.
Parts & tools for this fix
Taken from this code's causes or steps. A search link opens Amazon results and does not confirm a fit. Check the model number in the manual.
AC and heat pump coil cleaning supplies: guide
In this code: Count 4 short flashes and 9 long flashes. With power off, look at the outdoor coil for ice or debris. That is the airflow line on the fault 95 table this code points to
Multimeter for appliance and HVAC diagnosis: guide
In this code: Incoming power supply voltage, loose power leads, or a phase imbalance
This one is for a technician to test or replace, so we only explain it and do not link to buy it.