Affiliate links may earn us a commission. As an Amazon Associate I earn from qualifying purchases. Affiliate disclosure

Carrier 56: Outdoor air temperature and outdoor coil temperature thermistors are

Source: Carrier manual (PDF) (opens in a new tab) ↗ · Updated

Status code56Carrier
What does Carrier 56 mean?

Outdoor air temperature and outdoor coil temperature thermistors are out of range. The manual lists this as an event, not a lockout.

Homeowner part this code names: AC coil cleaner.

Search on Amazon

Opens an Amazon search for that name. Check the size against your manual. As an Amazon Associate I earn from qualifying purchases.

Call a pro: jump to when to call a pro Equipment type: AC / heat pump
How it shows: Amber status LED on a Carrier Infinity 25VNA8 heat pump or 24VNA9 air conditioner. Short flashes, then long flashes. Code 56 is 5 short flashes and 6 long flashes

Carrier 56 means the outdoor air and coil thermistors are out of range. Count 5 short and 6 long. The manual calls it an event. Causes include heating when cooling was called, a coil thermistor clipped in the wrong place, and an outdoor air sensor body touching sheet metal. One listed action is to inspect the outdoor coil for obstructions, with the power off. The reversing valve, if the unit heats in cooling, is technician work. It is not code 55's failed-sensor defrost rule.

Likely causes

  • Heating when cooling is demanded
  • Coil thermistor not properly attached, or attached in the wrong location
  • Outdoor ambient temperature sensor installed so the sensor body touches sheet metal

Safe checks for 56

  1. With the disconnect and breaker off, look at the outdoor coil for a blockage by debris or ice. The manual's action for this event includes inspecting the outdoor coil for obstructions
  2. Techniciantroubleshoot the reversing valve if the unit heats when cooling is demanded, confirm the coil thermistor is clipped to the distributor entry tube, and install the outdoor air sensor so it is not touching sheet metal
Safety firstOutdoor units carry line voltage even when the thermostat is off. Switch off the unit's disconnect and breaker before touching anything. Refrigerant, wiring, compressor and control-board work must be done by a licensed HVAC technician.

Capacitors can hold a charge after the power is off. Safety terms.

When to call a pro

Call a licensed HVAC technician if 56 returns after the outdoor coil is clear, or if the system heats when the thermostat is calling for cooling.

Find a Carrier dealer (official locator, opens in a new tab) ↗

Email me this fix

We save your email and this page. Nothing is emailed. We'll only use your email for this request.

Privacy. Deletion requests go to the address on that page.

Request a filter and maintenance reminder

We save your email, this page, and the interval you pick. Nothing is emailed. We'll only use your email for this request.

Privacy. Deletion requests go to the address on that page.

Parts & tools for this fix

Taken from this code's causes or steps. A search link opens Amazon results and does not confirm a fit. Check the model number in the manual.

AC and heat pump coil cleaning supplies: guide

In this code: Coil thermistor not properly attached, or attached in the wrong location

See the guide for what to look for when buying one.

Related Carrier AC / heat pump codes