67 codes · 6 brands

AC and heat pump error codes

What does your AC or heat pump fault code mean? These outdoor-unit and mini-split codes come from the manufacturer service manuals. Most need a licensed technician, so each page says which checks are safe and when to call a pro.

Last updated

These pages cover Carrier Infinity 25VNA8 / 24VNA9 outdoor units and Goodman (Daikin) ASXC, DSXC, GSXC, ASZC, DSZC and GSZC units with the integrated control module. Carrier reports faults as short and long flashes. Code 31 is a high-pressure switch opening; if it keeps happening on the lowest stage the control elevates to lockout 84 for four hours. Code 32 is a low-pressure trip and elevates to lockout 83 after three occurrences. Goodman shows 01 or L1 for a low-pressure cutout after three trips in one thermostat call, and 02 or L2 for a high-side fault after repeated compressor-protector trips. The manuals list airflow, ice and debris on the coils among the causes a homeowner can look at. Refrigerant charge, service valves, expansion devices and line voltage are technician work. Goodman L8 is the one voltage code whose manual tells you to see whether the breaker has tripped; measuring supply voltage is still a technician step. Outdoor units stay electrically live when the thermostat is off, until the disconnect and the breaker are both off. Mini-split charts are separate. On Daikin FTX30NVJU and FTX36NVJU, U4 is a signal transmission error between the indoor and outdoor units, and A5 is freeze-up protection or heating peak-cut. Mitsubishi MSZ-FS wall units blink the left operation lamp: 3 blinks is the indoor fan, 5 blinks is the outdoor power system, and a steady half-second blink is a serial-signal fault. Fujitsu ASUG09, ASUG12 and ASUG15 count the green operation lamp and the orange timer lamp: 1 and 1 is serial communication error 11, and 5 and 1 is indoor fan error 51. Those blink counts are the troubleshooting table, not a failure-recall mode.

Guides for this equipment: AC High and Low Pressure Codes · AC Voltage and Power Codes: Brownout, L8, H8, E5 · Heat Pump Not Heating in the Cold · How to Read a Bryant Evolution Outdoor Status Light. All guides.

Brands

Codes we cover

25Bryant · AC / heat pump

Invalid model plug or inverter size. The outdoor control does not accept the model plug fitted to this inverter. There is no reset time on this row.

31Bryant · AC / heat pump

High pressure switch open. The unit steps down capacity for each occurrence and elevates to fault 84 if it happens on the lowest stage. Reset time is 6 minutes, then the unit runs at a reduced stage.

32Bryant · AC / heat pump

Low pressure trip. The control elevates this to fault 83 after 3 occurrences. Reset time is 6 minutes. The manual's example of the flash pattern is 3 short and 2 long for code 32, and Table 6 calls that low pressure switch open.

33Bryant · AC / heat pump

Lost inverter communications, the local fault. It occurs after 2 minutes with no communication between the outdoor control and the inverter, and it elevates to fault 48 after 3 consecutive failures within 20 minutes or after 20 minutes of continuous loss.

46Bryant · AC / heat pump

Brownout. Line voltage at the outdoor unit is low. Reset time is 6 minutes.

48Bryant · AC / heat pump

Lost inverter communications, elevated from fault 33 after 3 occurrences. The outdoor control and the inverter are not talking.

53Bryant · AC / heat pump

Outdoor air temperature sensor fault. If this sensor fails, the manual says defrost is initiated from coil temperature and time. There is no reset time on this row.

55Bryant · AC / heat pump

Coil temperature sensor fault. If this sensor fails, the manual says defrost occurs at each time interval during heating and terminates after 2 minutes.

56Bryant · AC / heat pump

Outdoor air and coil thermistors out of range. The manual calls this an event. If the thermistors are out of range, defrost occurs at each heating interval and terminates after 2 minutes.

83Bryant · AC / heat pump

Low pressure lockout for 4 hours, elevated from fault 32 after 3 occurrences. The outdoor unit stops retrying the 6-minute trips.

84Bryant · AC / heat pump

High pressure lockout for 4 hours, elevated from fault 31 when the stage can no longer be lowered.

25Carrier · AC / heat pump

Invalid model plug / inverter size: the control does not accept the model plug for this inverter.

31Carrier · AC / heat pump

High pressure switch open: the unit steps down capacity for each occurrence and elevates to fault 84 if it happens on the lowest stage. Reset time is 6 minutes.

32Carrier · AC / heat pump

Low pressure trip: the control elevates to fault 83 (low pressure lockout) after 3 occurrences. Reset time is 6 minutes.

33Carrier · AC / heat pump

Lost inverter communications, the local fault. It is logged after 2 minutes with no communication between the outdoor control (AOC) and the inverter (MOC). It elevates to fault 48 after 3 consecutive failures within 20 minutes, or after 20 minutes of continuous loss of connection. The manual says to refer to fault code 48.

46Carrier · AC / heat pump

Brownout event: low line voltage reaching the unit. Reset time is 6 minutes.

48Carrier · AC / heat pump

Lost inverter communications (system malfunction): the outdoor control (AOC) and the inverter (MOC) have stopped communicating. Fault 33 is logged after 2 minutes with no communication and is elevated to 48 after 3 consecutive failures within 20 minutes, or 20 minutes of continuous loss of connection.

49Carrier · AC / heat pump

Compressor overcurrent fault. The control elevates this to fault 95 after 5 occurrences. Reset time is 6 minutes.

53Carrier · AC / heat pump

Outdoor air temperature sensor fault.

55Carrier · AC / heat pump

Coil temperature sensor fault.

56Carrier · AC / heat pump

Outdoor air temperature and outdoor coil temperature thermistors are out of range. The manual lists this as an event, not a lockout.

57Carrier · AC / heat pump

Suction pressure sensor fault. The suction pressure transducer reading cannot be trusted. There is no reset time on this row.

65Carrier · AC / heat pump

DC volts low, speed limiting. Supply voltage is under 197 V, or a loose wire or the inverter is limiting compressor speed. The table does not list a reset time.

83Carrier · AC / heat pump

Low pressure lockout for 4 hours, elevated from fault 32 after 3 occurrences.

84Carrier · AC / heat pump

High pressure lockout for 4 hours, elevated from fault 31 when the stage (speed) can no longer be lowered.

88Carrier · AC / heat pump

Compressor and inverter lockout for 2 hours, elevated from fault 79 after 5 occurrences. The compressor failed to start often enough that the control stopped the retries.

95Carrier · AC / heat pump

Compressor overcurrent lockout for 2 hours, elevated from fault 49 after 5 occurrences.

A5Daikin · mini-split

Freeze-up protection or heating peak-cut: the indoor heat exchanger got too cold in cooling or too hot in heating.

A6Daikin · mini-split

Indoor fan motor fault: the DC fan is not reaching the speed the control asked for.

E7Daikin · mini-split

Outdoor fan lock: the outdoor fan does not start within 15 to 30 seconds.

EADaikin · mini-split

Four-way valve abnormality: room temperature and indoor coil temperature stay out of range for the mode.

U4Daikin · mini-split

Signal transmission error between the indoor unit and the outdoor unit.

11Fujitsu · mini-split

Serial communication error: the indoor unit is not receiving the serial signal from the outdoor unit. The operation lamp blinks once and the timer lamp blinks once.

41Fujitsu · mini-split

Room temperature sensor error: the room-temperature thermistor is open or shorted. The operation lamp blinks 4 times and the timer lamp blinks once.

51Fujitsu · mini-split

Indoor fan motor error: fan speed stayed below one-third of the target for more than 56 seconds. The operation lamp blinks 5 times and the timer lamp blinks once.

63Fujitsu · mini-split

Inverter error: the outdoor unit received an error from the inverter board. The operation lamp blinks 6 times and the timer lamp blinks 3 times.

99Fujitsu · mini-split

4-way valve error: heat-exchanger temperature and room temperature stay too far apart for the mode. The operation lamp blinks 9 times and the timer lamp blinks 9 times.

01 / L1Goodman · AC / heat pump

Low pressure cutout: the low pressure switch tripped 3 times within the same thermostat call, so the compressor and outdoor fan are off.

02 / L2Goodman · AC / heat pump

High side fault: four consecutive compressor protector trips with average run time between trips of more than 1 minute and less than 15 minutes, with the low and high pressure switches closed.

03Goodman · AC / heat pump

Short cycling: the outdoor unit is cycling on and off too quickly.

04Goodman · AC / heat pump

Locked rotor: the compressor is not turning properly.

05Goodman · AC / heat pump

Open circuit. The compressor and outdoor fan have been off for more than 4 hours, and both pressure switches are closed.

06Goodman · AC / heat pump

Open start circuit. The compressor and outdoor fan are off, and both pressure switches are closed.

07Goodman · AC / heat pump

Open run circuit. The compressor and outdoor fan are off, and both pressure switches are closed.

08Goodman · AC / heat pump

No line voltage. The unit may appear to be operating normally, and the compressor protector may be open so the compressor and outdoor fan are off.

09Goodman · AC / heat pump

Low pilot voltage. The air conditioner or heat pump may appear to be operating normally. The chart's note says the control detects secondary voltage less than 18 VAC.

A2Goodman · AC / heat pump

Outdoor air temperature sensor fault. The integrated control module shows A2. The air conditioner or heat pump may show only this code, with no separate symptom line on this row.

A3Goodman · AC / heat pump

Outdoor coil temperature sensor fault. The chart says the heat pump fails to operate in heating mode, and the display shows A3.

b0Goodman · AC / heat pump

Circulator blower motor is not running when it should be. The air conditioner or heat pump fails to operate, and the display shows b0.

b9Goodman · AC / heat pump

Airflow is lower than demanded. The air conditioner or heat pump operates at reduced performance, or in low stage when high stage was expected. The display shows b9.

d0Goodman · AC / heat pump

Data not yet on the network. The air conditioner or heat pump fails to operate.

d1Goodman · AC / heat pump

Invalid data on the network. The air conditioner or heat pump fails to operate.

d2Goodman · AC / heat pump

System mismatch: the outdoor and indoor units are not an acceptable combination, or the airflow trim settings are set to a prohibited value.

d3Goodman · AC / heat pump

Configuration mismatch. The air conditioner or heat pump fails to operate.

d4Goodman · AC / heat pump

Invalid shared data. The air conditioner or heat pump fails to operate. The chart says the code clears once data is loaded.

E5Goodman · AC / heat pump

Open fuse: the low-voltage fuse on the control is blown.

EEGoodman · AC / heat pump

Board misoperation: the manual lists welded compressor relay contacts as the error condition.

H8Goodman · AC / heat pump

High line voltage: the unit may seem to run normally, but the compressor protector may be open (compressor and outdoor fan off).

L6Goodman · AC / heat pump

Open start-circuit lockout. The open start circuit was detected 4 times, with a 5-minute delay between each detection. The compressor and outdoor fan are off.

L7Goodman · AC / heat pump

Open run-circuit lockout. The open run circuit was detected 4 times, with a 5-minute delay between each detection. The compressor and outdoor fan are off.

L8Goodman · AC / heat pump

Low line voltage: the supply voltage to the outdoor unit is below the specified range.

P0Goodman · AC / heat pump

Compressor protector open. The compressor is off.

2 blinksMitsubishi · mini-split

Indoor coil or room thermistor fault: the sensor is shorted or open. The left lamp blinks twice, then pauses 2.5 seconds.

3 blinksMitsubishi · mini-split

Indoor fan motor fault: the fan is not reporting rotation. The left lamp blinks 3 times, then pauses 2.5 seconds.

5 blinksMitsubishi · mini-split

Outdoor power system fault: the compressor stopped three times for overcurrent or start-up failure within a minute of starting. The left lamp blinks 5 times.

7 blinksMitsubishi · mini-split

Outdoor control fault: the inverter board or outdoor control board cannot read its memory. The left lamp blinks 7 times.

Continuous blinkMitsubishi · mini-split

Miswiring or serial signal: the outdoor unit's serial signal was missing for 6 minutes. The left lamp blinks 0.5 second on and 0.5 second off, with no counted pause.

Parts and tools for AC / heat pump codes · Every page links its source · Last updated · Search every category

High voltageOutdoor units carry line voltage even when the thermostat is off. Switch off the disconnect and the breaker before opening any panel.