Goodman 02 / L2: High side fault

Source: Goodman manual (PDF) (opens in a new tab) ↗ · Updated

Status code02 / L2Goodman
What does Goodman 02 / L2 mean?

High side fault: four consecutive compressor protector trips with average run time between trips of more than 1 minute and less than 15 minutes, with the low and high pressure switches closed.

Homeowner part this code names: AC coil cleaner.

Search on Amazon

Opens an Amazon search for that name. Check the size against your manual. As an Amazon Associate I earn from qualifying purchases.

Call a pro: jump to when to call a pro Equipment type: AC / heat pump
How it shows: Outdoor control display reads 02 or L2

Goodman 02, also shown as L2, is a high-side fault. The manual defines it as four consecutive compressor protector trips with an average run time of more than 1 minute and less than 15 minutes, while both pressure switches stay closed. The display reads 02 or L2. Causes are high pressure on the system, a dirty condenser coil or a failed outdoor fan motor, and a failed capacitor or a wiring fault. Every step is marked for a technician: check the high pressure switch and cycle power if it is open, replace the switch if pressure is not high, and if pressure is high, check and clean the condenser coil and check the outdoor fan, the capacitor, and the wiring. The published warning is that those repeated protector trips can damage the compressor. Code 02 is not the low-pressure cutout 01 / L1, and it does not list a thermostat-setting step.

Likely causes

  • High pressure on the system
  • Dirty condenser coil or failed outdoor fan motor
  • Failed capacitor or wiring fault

Safe checks for 02 / L2

  1. Techniciancheck the resistance of the high pressure switch and cycle power if it is open; replace the switch if pressure is not high
  2. Technicianif pressure is high, check and clean the condenser coil, check the outdoor fan motor, the capacitor and the wiring, and repair or replace as needed
Safety firstOutdoor units carry line voltage even when the thermostat is off. Switch off the unit's disconnect and breaker before touching anything. Refrigerant, wiring, compressor and control-board work must be done by a licensed HVAC technician.

Capacitors can hold a charge after the power is off. Safety terms.

When to call a pro

Call a licensed HVAC technician: the repeated compressor protector trips can damage the compressor.

Find a Goodman dealer (official locator, opens in a new tab) ↗

Email me this fix

We save your email and this page. Nothing is emailed. We'll only use your email for this request.

Privacy. Deletion requests go to the address on that page.

Request a filter and maintenance reminder

We save your email, this page, and the interval you pick. Nothing is emailed. We'll only use your email for this request.

Privacy. Deletion requests go to the address on that page.

Parts & tools for this fix

Taken from this code's causes or steps. A search link opens Amazon results and does not confirm a fit. Check the model number in the manual.

Run capacitor (furnace blower and AC): guide

In this code: Failed capacitor or wiring fault

This one is for a technician to test or replace, so we only explain it and do not link to buy it.

Multimeter for appliance and HVAC diagnosis: guide

Technician step in this code: check the resistance of the high pressure switch and cycle power if it is open; replace the switch if pressure is not high

This one is for a technician to test or replace, so we only explain it and do not link to buy it.

As an Amazon Associate I earn from qualifying purchases.Affiliate disclosure