Goodman 05: Open circuit

Source: Goodman manual (PDF) (opens in a new tab) ↗ · Updated

Status code05Goodman
What does Goodman 05 mean?

Open circuit. The compressor and outdoor fan have been off for more than 4 hours, and both pressure switches are closed.

Call a pro: jump to when to call a pro Equipment type: AC / heat pump
How it shows: PCBHR104 unitary diagnostic display in Goodman service manual RS6200007 r27. Digit 3 is blank. Digit 2 is 0 and digit 1 is 5. The code is 05

Likely causes

  • Power is disconnected
  • Failed compressor protector
  • Compressor not wired to the control the way the chart requires

Safe checks for 05

  1. Check the circuit breakers and fuses. That is the first action on the 05 row. If a breaker trips again as soon as the unit starts, leave it off
  2. Techniciancheck wiring to the unit, the compressor, and the compressor wiring. The chart says the fault clears after 1 normal cycle, or by cycling 24 VAC to the control
Safety firstOutdoor units carry line voltage even when the thermostat is off. Switch off the unit's disconnect and breaker before touching anything. Refrigerant, wiring, compressor and control-board work must be done by a licensed HVAC technician.

Capacitors can hold a charge after the power is off. Safety terms.

When to call a pro

Call a licensed HVAC technician if the breakers and fuses are intact and 05 remains. An open compressor circuit is not a coil-cleaning code.

Find a Goodman dealer (official locator, opens in a new tab) ↗

Email me this fix

We save your email and this page. Nothing is emailed. We'll only use your email for this request.

Privacy. Deletion requests go to the address on that page.