Goodman AC / heat pump error codes

Last updated

What does your Goodman AC / heat pump error code mean? 25 codes from official Goodman AC / heat pump documentation. Select a code for causes, how to fix it safely and when to call a pro. Goodman manufacturer manual (PDF) (opens in a new tab) ↗.

25 of these 25 Goodman AC / heat pump pages are marked call-a-pro because the source document points at gas, venting, refrigerant, high voltage or a control the manual does not leave to a homeowner. The other 0 start with a check the document describes, then say when to stop.

Related guides: AC High and Low Pressure Codes · AC Voltage and Power Codes: Brownout, L8, H8, E5 · Heat Pump Not Heating in the Cold · How to Read a Bryant Evolution Outdoor Status Light.

01 / L1AC / heat pump

Low pressure cutout: the low pressure switch tripped 3 times within the same thermostat call, so the compressor and outdoor fan are off.

Call a pro
02 / L2AC / heat pump

High side fault: four consecutive compressor protector trips with average run time between trips of more than 1 minute and less than 15 minutes, with the low and high pressure switches closed.

Call a pro
03AC / heat pump

Short cycling: the outdoor unit is cycling on and off too quickly.

Call a pro
04AC / heat pump

Locked rotor: the compressor is not turning properly.

Call a pro
05AC / heat pump

Open circuit. The compressor and outdoor fan have been off for more than 4 hours, and both pressure switches are closed.

Call a pro
06AC / heat pump

Open start circuit. The compressor and outdoor fan are off, and both pressure switches are closed.

Call a pro
07AC / heat pump

Open run circuit. The compressor and outdoor fan are off, and both pressure switches are closed.

Call a pro
08AC / heat pump

No line voltage. The unit may appear to be operating normally, and the compressor protector may be open so the compressor and outdoor fan are off.

Call a pro
09AC / heat pump

Low pilot voltage. The air conditioner or heat pump may appear to be operating normally. The chart's note says the control detects secondary voltage less than 18 VAC.

Call a pro
A2AC / heat pump

Outdoor air temperature sensor fault. The integrated control module shows A2. The air conditioner or heat pump may show only this code, with no separate symptom line on this row.

Call a pro
A3AC / heat pump

Outdoor coil temperature sensor fault. The chart says the heat pump fails to operate in heating mode, and the display shows A3.

Call a pro
b0AC / heat pump

Circulator blower motor is not running when it should be. The air conditioner or heat pump fails to operate, and the display shows b0.

Call a pro
b9AC / heat pump

Airflow is lower than demanded. The air conditioner or heat pump operates at reduced performance, or in low stage when high stage was expected. The display shows b9.

Call a pro
d0AC / heat pump

Data not yet on the network. The air conditioner or heat pump fails to operate.

Call a pro
d1AC / heat pump

Invalid data on the network. The air conditioner or heat pump fails to operate.

Call a pro
d2AC / heat pump

System mismatch: the outdoor and indoor units are not an acceptable combination, or the airflow trim settings are set to a prohibited value.

Call a pro
d3AC / heat pump

Configuration mismatch. The air conditioner or heat pump fails to operate.

Call a pro
d4AC / heat pump

Invalid shared data. The air conditioner or heat pump fails to operate. The chart says the code clears once data is loaded.

Call a pro
E5AC / heat pump

Open fuse: the low-voltage fuse on the control is blown.

Call a pro
EEAC / heat pump

Board misoperation: the manual lists welded compressor relay contacts as the error condition.

Call a pro
H8AC / heat pump

High line voltage: the unit may seem to run normally, but the compressor protector may be open (compressor and outdoor fan off).

Call a pro
L6AC / heat pump

Open start-circuit lockout. The open start circuit was detected 4 times, with a 5-minute delay between each detection. The compressor and outdoor fan are off.

Call a pro
L7AC / heat pump

Open run-circuit lockout. The open run circuit was detected 4 times, with a 5-minute delay between each detection. The compressor and outdoor fan are off.

Call a pro
L8AC / heat pump

Low line voltage: the supply voltage to the outdoor unit is below the specified range.

Call a pro
P0AC / heat pump

Compressor protector open. The compressor is off.

Call a pro

Parts named in Goodman codes

Parts the Goodman codes above point to. Check your model's manual before buying.

Search on Amazon opens search results for the part name. It does not confirm a fit. As an Amazon Associate I earn from qualifying purchases.

Parts and tools for Goodman AC / heat pump codes →

Source: Goodman manufacturer manual (PDF) (opens in a new tab) ↗ · Last updated

High voltageOutdoor units carry line voltage even when the thermostat is off. Switch off the disconnect and the breaker before opening any panel.