Goodman 01 / L1: Low pressure cutout

Source: Goodman manual (PDF) (opens in a new tab) ↗ · Updated

Status code01 / L1Goodman
What does Goodman 01 / L1 mean?

Low pressure cutout: the low pressure switch tripped 3 times within the same thermostat call, so the compressor and outdoor fan are off.

Homeowner part this code names: thermostat.

Search on Amazon

Opens an Amazon search for that name. Check the size against your manual. As an Amazon Associate I earn from qualifying purchases.

Call a pro: jump to when to call a pro Equipment type: AC / heat pump
How it shows: Outdoor control display reads 01 or L1

Goodman 01, also shown as L1, is a low-pressure cutout. The low pressure switch tripped 3 times during the same thermostat call, so the compressor and the outdoor fan are off. The outdoor display reads 01 or L1. Causes are an open low pressure switch, low refrigerant charge or a restriction, low indoor airflow, the thermostat setting, and a supply-voltage problem. The homeowner step is the thermostat setting and anything restricting indoor airflow. The manual says to verify indoor airflow, charge, and the thermostat setting. Charge is the technician half of that sentence. Technician steps are to read the switch resistance, read pressure on a gauge, and replace the switch only if the pressure is not low. If the pressure is low, verify airflow and charge, and check the voltage wires, involving the electric company if needed. This is not the high-side fault 02 / L2.

Likely causes

  • Open low pressure switch
  • Low refrigerant charge or a restriction
  • Low indoor airflow
  • Thermostat setting
  • Supply voltage problem

Safe checks for 01 / L1

  1. Check the thermostat setting and look for anything restricting indoor airflow (the manual says to verify indoor airflow, charge and thermostat setting)
  2. Techniciancheck the resistance of the low pressure switch; read the pressure on a gauge and replace the switch if the pressure is not low
  3. Technicianif the pressure is low, verify indoor airflow and refrigerant charge, and check voltage wires (involve the electric company if needed)
Safety firstOutdoor units carry line voltage even when the thermostat is off. Switch off the unit's disconnect and breaker before touching anything. Refrigerant, wiring, compressor and control-board work must be done by a licensed HVAC technician.

Capacitors can hold a charge after the power is off. Safety terms.

When to call a pro

Call a licensed HVAC technician: low pressure lockouts involve refrigerant and pressure readings.

Find a Goodman dealer (official locator, opens in a new tab) ↗

Email me this fix

We save your email and this page. Nothing is emailed. We'll only use your email for this request.

Privacy. Deletion requests go to the address on that page.

Request a filter and maintenance reminder

We save your email, this page, and the interval you pick. Nothing is emailed. We'll only use your email for this request.

Privacy. Deletion requests go to the address on that page.

Parts & tools for this fix

Taken from this code's causes or steps. A search link opens Amazon results and does not confirm a fit. Check the model number in the manual.

Multimeter for appliance and HVAC diagnosis: guide

In this code: Supply voltage problem

This one is for a technician to test or replace, so we only explain it and do not link to buy it.

As an Amazon Associate I earn from qualifying purchases.Affiliate disclosure

Related Goodman AC / heat pump codes

All Goodman AC / heat pump codes →Browse every code