Status code07Goodman
What does Goodman 07 mean?
Open run circuit. The compressor and outdoor fan are off, and both pressure switches are closed.
Call a pro: jump to when to call a pro Equipment type: AC / heat pump
How it shows: PCBHR104 unitary diagnostic display in Goodman service manual RS6200007 r27. Digit 3 is blank. Digit 2 is 0 and digit 1 is 7. The code is 07
Likely causes
- Compressor run winding is open
- Compressor not wired to the control
- Faulty compressor wiring
Safe checks for 07
- Write down 07. It is the open run circuit, not the start-circuit code 06 and not lockout L7
- Techniciancheck the compressor and the wiring. The chart says the fault clears after 1 normal cycle, or by cycling 24 VAC to the control
Safety firstOutdoor units carry line voltage even when the thermostat is off. Switch off the unit's disconnect and breaker before touching anything. Refrigerant, wiring, compressor and control-board work must be done by a licensed HVAC technician.
Capacitors can hold a charge after the power is off. Safety terms.
When to call a pro
Call a licensed HVAC technician. An open run winding is compressor diagnosis, not a homeowner reset.