Goodman L6: Open start-circuit lockout

Source: Goodman manual (PDF) (opens in a new tab) ↗ · Updated

Status codeL6Goodman
What does Goodman L6 mean?

Open start-circuit lockout. The open start circuit was detected 4 times, with a 5-minute delay between each detection. The compressor and outdoor fan are off.

Call a pro: jump to when to call a pro Equipment type: AC / heat pump
How it shows: PCBHR104 unitary diagnostic display in Goodman service manual RS6200007 r27. Digit 3 is blank. Digit 2 is L and digit 1 is 6. The code is L6

Likely causes

  • Compressor start winding is open
  • Failed run capacitor
  • Faulty run-capacitor wiring
  • Compressor not wired to the control, or other faulty compressor wiring

Safe checks for L6

  1. Write down L6. The single open-start trip is 06. L6 is the lockout after four detections
  2. Techniciancheck the compressor, the run capacitor, and the wiring. The chart says this lockout must be cleared by cycling 24 VAC to the control
Safety firstOutdoor units carry line voltage even when the thermostat is off. Switch off the unit's disconnect and breaker before touching anything. Refrigerant, wiring, compressor and control-board work must be done by a licensed HVAC technician.

Capacitors can hold a charge after the power is off. Safety terms.

When to call a pro

Call a licensed HVAC technician. Do not keep resetting power to force another start. The chart already counted four detections.

Find a Goodman dealer (official locator, opens in a new tab) ↗

Email me this fix

We save your email and this page. Nothing is emailed. We'll only use your email for this request.

Privacy. Deletion requests go to the address on that page.

Request a filter and maintenance reminder

We save your email, this page, and the interval you pick. Nothing is emailed. We'll only use your email for this request.

Privacy. Deletion requests go to the address on that page.

Parts & tools for this fix

Taken from this code's causes or steps. A search link opens Amazon results and does not confirm a fit. Check the model number in the manual.

Run capacitor (furnace blower and AC): guide

In this code: Failed run capacitor

This one is for a technician to test or replace, so we only explain it and do not link to buy it.

Related Goodman AC / heat pump codes

All Goodman AC / heat pump codes →Browse every code