Carrier 31: High pressure switch open

Source: Carrier manual (PDF) (opens in a new tab) ↗ · Updated

Status code31Carrier
What does Carrier 31 mean?

High pressure switch open: the unit steps down capacity for each occurrence and elevates to fault 84 if it happens on the lowest stage. Reset time is 6 minutes.

Homeowner part this code names: AC coil cleaner.

Search on Amazon

Opens an Amazon search for that name. Check the size against your manual. As an Amazon Associate I earn from qualifying purchases.

Call a pro: jump to when to call a pro Equipment type: AC / heat pump
How it shows: Status LED: 3 short flashes then 1 long flash

Carrier 31 means the high pressure switch opened. It is the warning, not the 4-hour lockout. Count 3 short flashes and 1 long flash. Each time the switch opens, the unit steps down a stage. Reset time is 6 minutes. If the switch opens again when the stage can no longer be lowered, the control elevates to fault 84. The manual points 31 at the fault 84 cause list: high outdoor or indoor load or an airflow problem, overcharge, a closed service valve, a restriction in the filter drier or expansion device, a loose or disconnected pressure switch, and a faulty pressure switch. The homeowner line for 31 is the outdoor coil: look for ice or debris, and clean or de-ice it with the power off. Troubleshooting the outdoor fan motor, the charge, the valves, the filter drier, and the switch harness is technician work. Code 31 does not use code 32's cooling-mode indoor-coil check.

Same characters, different appliance: Carrier 31 on a furnace is a different fault. Carrier furnace 31.

Likely causes

  • The service manual points code 31 at the fault 84 cause list
  • High outdoor or indoor load, or an airflow problem
  • Overcharge
  • Closed service valve
  • Restriction in the filter drier or expansion device
  • Loose or disconnected pressure switch
  • Faulty pressure switch

Safe checks for 31

  1. Check the outdoor coil for clogging by ice or debris and clean or de-ice it if necessary (the manual also says to troubleshoot the outdoor fan motor)
  2. Technicianfollow the fault 84 table (charge, service valves, filter drier, expansion device, pressure switch harness and connection)
Safety firstOutdoor units carry line voltage even when the thermostat is off. Switch off the unit's disconnect and breaker before touching anything. Refrigerant, wiring, compressor and control-board work must be done by a licensed HVAC technician.

Capacitors can hold a charge after the power is off. Safety terms.

When to call a pro

Call a licensed HVAC technician if 31 repeats or escalates to 84.

Find a Carrier dealer (official locator, opens in a new tab) ↗

Email me this fix

We save your email and this page. Nothing is emailed. We'll only use your email for this request.

Privacy. Deletion requests go to the address on that page.

Request a filter and maintenance reminder

We save your email, this page, and the interval you pick. Nothing is emailed. We'll only use your email for this request.

Privacy. Deletion requests go to the address on that page.

Parts & tools for this fix

Taken from this code's causes or steps. A search link opens Amazon results and does not confirm a fit. Check the model number in the manual.

AC and heat pump coil cleaning supplies: guide

In this code: Check the outdoor coil for clogging by ice or debris and clean or de-ice it if necessary (the manual also says to troubleshoot the outdoor fan motor)

As an Amazon Associate I earn from qualifying purchases.Affiliate disclosure

Related Carrier AC / heat pump codes

All Carrier AC / heat pump codes →Browse every code