Carrier 95: Compressor overcurrent lockout for 2 hours, elevated from fault 49

Source: Carrier manual (PDF) (opens in a new tab) ↗ · Updated

Status code95Carrier
What does Carrier 95 mean?

Compressor overcurrent lockout for 2 hours, elevated from fault 49 after 5 occurrences.

Homeowner part this code names: AC coil cleaner.

Search on Amazon

Opens an Amazon search for that name. Check the size against your manual. As an Amazon Associate I earn from qualifying purchases.

Call a pro: jump to when to call a pro Equipment type: AC / heat pump
How it shows: Amber status LED on a Carrier Infinity 25VNA8 heat pump or 24VNA9 air conditioner. A short flash is 0.25 seconds on and a long flash is 1.0 second on. Code 95 is 9 short and 5 long

Carrier 95 is the compressor overcurrent lockout for 2 hours, elevated from fault 49 after 5 occurrences. The 6-minute event is code 49. Causes include high superheat, the compressor outside its allowed envelope, supply voltage, loose connections, phase imbalance, low outdoor airflow, overcharge, inverter damage, and compressor internal damage. The outdoor-coil check is the airflow line. Voltage is compared with the rating plate, not with code 46's 180 V figure.

Likely causes

  • High superheat, or the compressor operating outside its allowed envelope
  • Incoming supply voltage outside the rating plate, or loose power connections
  • Phase imbalance or miswired compressor leads at U, V, and W
  • Outdoor airflow too low or off
  • Refrigerant overcharge
  • Inverter damage or compressor internal damage

Safe checks for 95

  1. With power off, check the outdoor coil for ice or debris. The table pairs that look with troubleshooting the outdoor fan
  2. Techniciancheck voltage against the rating plate, winding resistance and lead wiring, superheat, the suction transducer, charge, and replace the inverter or compressor only if those checks say so
Safety firstOutdoor units carry line voltage even when the thermostat is off. Switch off the unit's disconnect and breaker before touching anything. Refrigerant, wiring, compressor and control-board work must be done by a licensed HVAC technician.

Capacitors can hold a charge after the power is off. Safety terms.

When to call a pro

Call a licensed HVAC technician. Code 49 was still resetting every 6 minutes. 95 is the 2-hour lockout.

Find a Carrier dealer (official locator, opens in a new tab) ↗

Email me this fix

We save your email and this page. Nothing is emailed. We'll only use your email for this request.

Privacy. Deletion requests go to the address on that page.

Request a filter and maintenance reminder

We save your email, this page, and the interval you pick. Nothing is emailed. We'll only use your email for this request.

Privacy. Deletion requests go to the address on that page.

Parts & tools for this fix

Taken from this code's causes or steps. A search link opens Amazon results and does not confirm a fit. Check the model number in the manual.

AC and heat pump coil cleaning supplies: guide

In this code: With power off, check the outdoor coil for ice or debris. The table pairs that look with troubleshooting the outdoor fan

Multimeter for appliance and HVAC diagnosis: guide

In this code: Incoming supply voltage outside the rating plate, or loose power connections

This one is for a technician to test or replace, so we only explain it and do not link to buy it.

As an Amazon Associate I earn from qualifying purchases.Affiliate disclosure

Related Carrier AC / heat pump codes

All Carrier AC / heat pump codes →Browse every code