Bryant 84: High pressure lockout for 4 hours, elevated from fault 31 when the

Source: Bryant manual (PDF) (opens in a new tab) ↗ · Updated

Status code84Bryant
What does Bryant 84 mean?

High pressure lockout for 4 hours, elevated from fault 31 when the stage can no longer be lowered.

Homeowner part this code names: AC coil cleaner.

Search on Amazon

Opens an Amazon search for that name. Check the size against your manual. As an Amazon Associate I earn from qualifying purchases.

Call a pro: jump to when to call a pro Equipment type: AC / heat pump
How it shows: Amber status LED on a Bryant 288BNV Evolution heat pump or 189BNV air conditioner. A short flash is 0.25 seconds on and a long flash is 1.0 second on. Code 84 is 8 short and 4 long

Bryant outdoor 84 is a high-pressure lockout for 4 hours, elevated from fault 31 when the stage can no longer be lowered. Causes include low outdoor airflow in cooling, low indoor airflow in heating, overcharge, a service valve left closed, a loose high-pressure-switch harness, a restricted filter drier, non-condensables, a faulty pressure switch, and a reversing valve stuck in cooling. In heating, the homeowner check is the indoor coil and the filter. Also check the outdoor coil for ice or debris.

Likely causes

  • Outdoor airflow too low or off in cooling, including a coil blocked by ice or debris
  • Indoor airflow too low or off in heating
  • Overcharged system, closed service valve, or non-condensables
  • Loose high-pressure-switch harness, or the switch disconnected from the inverter
  • Restricted filter drier or expansion device
  • Reversing valve stuck in cooling during a heating call
  • On a furnace-plus-heat-pump system, the furnace running when it should not

Safe checks for 84

  1. In heating, with power off, check the indoor coil and the filter for debris. Also check the outdoor coil for ice or debris
  2. Technicianthe table says to check discharge pressure with a gauge, and to replace the pressure switch if pressure is less than 600 plus or minus 20 psig and the switch is open. Charge, valves, and the reversing valve are the same visit
Safety firstOutdoor units carry line voltage even when the thermostat is off. Switch off the unit's disconnect and breaker before touching anything. Refrigerant, wiring, compressor and control-board work must be done by a licensed HVAC technician.

Capacitors can hold a charge after the power is off. Safety terms.

When to call a pro

Call a licensed HVAC technician if 84 is stored. Code 31 was still stepping the unit down. 84 is the control stopping that.

Find a Bryant dealer (official locator, opens in a new tab) ↗

Email me this fix

We save your email and this page. Nothing is emailed. We'll only use your email for this request.

Privacy. Deletion requests go to the address on that page.

Request a filter and maintenance reminder

We save your email, this page, and the interval you pick. Nothing is emailed. We'll only use your email for this request.

Privacy. Deletion requests go to the address on that page.

Parts & tools for this fix

Taken from this code's causes or steps. A search link opens Amazon results and does not confirm a fit. Check the model number in the manual.

Furnace and AC air filter: guide

In this code: In heating, with power off, check the indoor coil and the filter for debris. Also check the outdoor coil for ice or debris

See the guide for what to look for when buying one.

As an Amazon Associate I earn from qualifying purchases.Affiliate disclosure

Related Bryant AC / heat pump codes

All Bryant AC / heat pump codes →Browse every code