Bryant 32: Low pressure trip

Source: Bryant manual (PDF) (opens in a new tab) ↗ · Updated

Status code32Bryant
What does Bryant 32 mean?

Low pressure trip. The control elevates this to fault 83 after 3 occurrences. Reset time is 6 minutes. The manual's example of the flash pattern is 3 short and 2 long for code 32, and Table 6 calls that low pressure switch open.

Homeowner part this code names: AC coil cleaner.

Search on Amazon

Opens an Amazon search for that name. Check the size against your manual. As an Amazon Associate I earn from qualifying purchases.

Call a pro: jump to when to call a pro Equipment type: AC / heat pump
How it shows: Amber status LED on a Bryant 288BNV Evolution heat pump or 189BNV air conditioner. A short flash is 0.25 seconds on and a long flash is 1.0 second on. Code 32 is 3 short and 2 long

Bryant outdoor 32 is a low pressure trip, not the high-pressure switch. It elevates to fault 83 after 3 occurrences. Reset time is 6 minutes. Table 6 says to use the fault 83 checks: a closed service valve, low charge, low indoor airflow in cooling, low outdoor airflow in heating, and a restriction in the filter drier or expansion device. Code 31 is the high-pressure switch. Furnace code 32 is the furnace low-heat pressure switch.

Same characters, different appliance: Bryant 32 on a furnace is a different fault. Bryant furnace 32.

Likely causes

  • The service manual points code 32 at the fault 83 cause list
  • Service valve left closed
  • Undercharged system
  • Indoor airflow too low in cooling, or outdoor airflow too low in heating
  • Restriction in the filter drier, expansion device, circuits, or tubing

Safe checks for 32

  1. In cooling, with power off, check the indoor coil for ice or debris. Also look at the outdoor coil for ice or debris
  2. Technicianfollow the fault 83 table for charge, service valves, the EXV or TXV, and the filter drier
Safety firstOutdoor units carry line voltage even when the thermostat is off. Switch off the unit's disconnect and breaker before touching anything. Refrigerant, wiring, compressor and control-board work must be done by a licensed HVAC technician.

Capacitors can hold a charge after the power is off. Safety terms.

When to call a pro

Call a licensed HVAC technician if 32 repeats or becomes the 4-hour lockout 83. Do not add refrigerant.

Find a Bryant dealer (official locator, opens in a new tab) ↗

Email me this fix

We save your email and this page. Nothing is emailed. We'll only use your email for this request.

Privacy. Deletion requests go to the address on that page.

Request a filter and maintenance reminder

We save your email, this page, and the interval you pick. Nothing is emailed. We'll only use your email for this request.

Privacy. Deletion requests go to the address on that page.

Parts & tools for this fix

Taken from this code's causes or steps. A search link opens Amazon results and does not confirm a fit. Check the model number in the manual.

AC and heat pump coil cleaning supplies: guide

In this code: In cooling, with power off, check the indoor coil for ice or debris. Also look at the outdoor coil for ice or debris

As an Amazon Associate I earn from qualifying purchases.Affiliate disclosure