What it is
The high limit switch opens if the furnace overheats. The flame rollout switch opens if flame rolls out of the burner compartment. Both are safety devices. Lennox, Trane and Carrier list dirty filters, blower faults, restricted flue piping and burner misalignment among the causes.
Trane says never to leave limit switches jumpered.
How to choose
- We do not link replacement limit or rollout switches. Replacing a safety switch without finding why it opened is exactly the situation the manuals warn about.
How it is tested
- Start with the cheap, safe cause: a dirty filter (see the air filter guide).
- Everything beyond that (static pressure, heat rise, flue, burners, gas pressure) is a technician check.
Replacing it
- Technician only.
Capacitors can hold a charge after the power is off. Safety terms.
Where to buy
We do not link replacement safety switches. Replacing one without finding out why it opened is the situation the manuals warn about, so this page explains the part and leaves it to a technician.
Codes that mention it
Error codes whose own causes or steps name this part or check.
Amana
American Standard
Bryant
Carrier
Goodman
Lennox
Rheem
Trane
Per-brand lists: Amana furnace · American Standard furnace · Bryant furnace · Carrier furnace · Goodman furnace · Lennox furnace · Rheem furnace · Trane furnace · York furnace.
Sources
- Trane S9V2 Service Facts (S9V2-SF-2A-EN) (opens in a new tab) ↗
- Carrier 59SC5 installation, start-up & operating instructions (opens in a new tab) ↗
- Lennox ML180UH installation & operation manual (opens in a new tab) ↗
- Goodman GR9S96/GD9S96 installation & operating guide (IOG-2037B) (opens in a new tab) ↗