Bryant 13: Limit circuit lockout

Source: Bryant manual (PDF) (opens in a new tab) ↗ · Updated

Status code13Bryant
What does Bryant 13 mean?

Limit circuit lockout. The limit or flame rollout switch was open longer than 3 minutes, or 10 successive limit trips occurred during high heat. The control auto-resets after 3 hours. The manual says to see status code 33.

How it shows: Amber status LED on a Bryant 926TB: short flashes, then long flashes. Code 13 is 1 short flash and 3 long flashes

Bryant 926TB code 13 is the limit-circuit lockout. Count 1 short flash and 3 long flashes. The troubleshooting guide says the limit or the flame rollout switch was open longer than 3 minutes, or high heat had 10 limit trips in a row. The control auto-resets after 3 hours and says to see code 33 for the fault itself. This page does not invent a code 33 cause list. If rollout opened, leave the furnace off.

Likely causes

  • Limit switch open longer than 3 minutes
  • Flame rollout switch open longer than 3 minutes
  • 10 successive limit trips during high heat

Safe checks for 13

  1. Count 1 short flash and 3 long flashes before you cut power. The 3-hour auto-reset is not a repair
  2. If a rollout switch has opened, leave the furnace off. Do not reset it and walk away
  3. Technicianuse status code 33, which this lockout points to, to find which switch opened
Safety firstIf you smell gas, do not touch any electrical switch or use a phone in the building; leave immediately and call your gas supplier from outside. Turn off electrical power at the furnace switch or breaker before opening any panel, and never bypass or jumper a limit, rollout or pressure switch. Gas valve, burner, venting, wiring and control-board work should be done by a licensed HVAC technician.

Capacitors can hold a charge after the power is off. Safety terms.

When to call a pro

Call a licensed HVAC technician if 13 is stored. This Bryant page only states what code 13 itself says. It does not copy another brand's cause list onto code 33.

Find a Bryant dealer (official locator, opens in a new tab) ↗

Email me this fix

We save your email and this page. Nothing is emailed. We'll only use your email for this request.

Privacy. Deletion requests go to the address on that page.

Request a filter and maintenance reminder

We save your email, this page, and the interval you pick. Nothing is emailed. We'll only use your email for this request.

Privacy. Deletion requests go to the address on that page.

Parts & tools for this fix

Taken from this code's causes or steps. A search link opens Amazon results and does not confirm a fit. Check the model number in the manual.

High limit and rollout switches: guide

In this code: Limit switch open longer than 3 minutes

A safety device: we explain it but do not link to buy one.

Related Bryant codes

All Bryant codes →Browse every code