Codes that name it
Amana
- Amana furnace EE3:
Loose or improperly connected wiring in the high limit circuit
Amana and Goodman *CVC96 / *MVC96 two-stage furnace installation instructions (IOG-2015L) (opens in a new tab) ↗ - Amana furnace EEd:
Loose wiring in the auxiliary limit circuit
Amana and Goodman *CVC96 / *MVC96 two-stage furnace installation instructions (IOG-2015L) (opens in a new tab) ↗
American Standard
Bryant
- Bryant furnace 13:
Limit switch open longer than 3 minutes
Bryant 926TB installation, start-up, operating and service instructions (opens in a new tab) ↗ - Bryant furnace 33:
Limit circuit fault. A limit, draft safeguard, flame rollout, or blocked-vent switch is open, or the furnace is in high-heat only after two successive low-heat limit trips. The blower runs for 4 minutes or until the switch remakes, whichever is longer. Open longer than 3 minutes becomes lockout 13.
Bryant 80% variable-speed two-stage furnace troubleshooting guide (Catalog No. TG-GFB80-02) (opens in a new tab) ↗
Carrier
- Carrier furnace 13:
Limit circuit lockout: a limit or flame rollout switch was open longer than 3 minutes. Control auto-resets after 3 hours (see code 33).
Carrier 59SC5 installation, start-up and operating instructions (opens in a new tab) ↗ - Carrier furnace 33:
Limit circuit fault: a limit or flame rollout switch is open. Becomes lockout 13 if open longer than 3 minutes.
Carrier 59SC5 installation, start-up and operating instructions (opens in a new tab) ↗
Goodman
- Goodman furnace EE3:
Loose or improperly connected wiring in the high limit circuit
Goodman GR9S96/GD9S96 installation and operating guide (IOG-2037B) (opens in a new tab) ↗
Lennox
- Lennox furnace Red slow flash, green on:
Limit switch open (overheating condition)
Lennox ML180UH installation and operation manual (opens in a new tab) ↗
Trane
- Trane furnace E04:
Open limit: main thermal limit, flame rollout switch, or reverse airflow switch.
Trane S9V2 Service Facts (S9V2-SF-2A-EN) (opens in a new tab) ↗
York
Technician part
Limit and rollout switches are safety devices. This page names the codes that mention them and leaves replacement to a licensed technician.
Safety first
Unplug the furnace or switch it off at the breaker, and shut off the gas supply where relevant, before you open any panel. Capacitors can hold a charge after power is off. Gas, electrical-panel, refrigerant and carbon-monoxide work belongs to a licensed professional. Follow the manual for your model (safety terms).