Codes that name it
Amana
American Standard
- American Standard furnace E12:
Open fuse on the furnace control
American Standard S9V2 installer's guide (18-CE01D1-1E-EN) (opens in a new tab) ↗
Bryant
- Bryant furnace 24:
Secondary voltage fuse is open. The chart says to check for a short circuit in the secondary (24 V) wiring.
Bryant 80% variable-speed two-stage furnace troubleshooting guide (Catalog No. TG-GFB80-02) (opens in a new tab) ↗
Carrier
- Carrier furnace 24:
Secondary voltage (24 V) fuse is open.
Carrier 59SC5 installation, start-up and operating instructions (opens in a new tab) ↗
Goodman
Rheem
- Rheem furnace 30:
Open fuse, usually from a 24 VAC short to common or ground.
Rheem R96V installation instructions (92-24161-124-03) (opens in a new tab) ↗
Trane
- Trane furnace E12:
Accessory drawing more than the fuse rating
Trane S9V2 Service Facts (S9V2-SF-2A-EN) (opens in a new tab) ↗
Search for this part
The button opens an Amazon search for the part name. It does not confirm a fit for your model, and it does not make the repair a homeowner job. Gas, venting and line-voltage work belongs to a licensed technician.
As an Amazon Associate I earn from qualifying purchases. Affiliate disclosure
Unplug the furnace or switch it off at the breaker, and shut off the gas supply where relevant, before you open any panel. Capacitors can hold a charge after power is off. Gas, electrical-panel, refrigerant and carbon-monoxide work belongs to a licensed professional. Follow the manual for your model (safety terms).