What the manuals say about cleaning
Goodman GR9S96/GD9S96 installation and operating guide (IOG-2037B) says the flame sensor should be carefully cleaned by a qualified servicer using emery cloth or steel wool. Goodman IOG-2037B (opens in a new tab) ↗
Rheem R96V installation instructions recommend that at the beginning of the heating season the flame sensor be cleaned with fine steel wool or a Scotch Bright Pad by a qualified installer, service agency or the gas supplier. Rheem R96V installation instructions (opens in a new tab) ↗
Codes that name it
Amana
- Amana furnace EE0:
Flame sensor coated or oxidized
Amana and Goodman *CVC96 / *MVC96 two-stage furnace installation instructions (IOG-2015L) (opens in a new tab) ↗ - Amana furnace EE4:
Technician: correct a short at the flame sensor or in the flame sensor wiring, and check for a lingering or lazy flame and gas valve operation
Amana and Goodman *CVC96 / *MVC96 two-stage furnace installation instructions (IOG-2015L) (opens in a new tab) ↗ - Amana furnace EE6:
Flame sensor coated or oxidized
Amana and Goodman *CVC96 / *MVC96 two-stage furnace installation instructions (IOG-2015L) (opens in a new tab) ↗
American Standard
- American Standard furnace E2.2:
Technician: the heating sequence in this guide proves flame at the flame sensor within 4 seconds, typically 0.75 to 3.0 microamps
American Standard S9V2 installer's guide (18-CE01D1-1E-EN) (opens in a new tab) ↗ - American Standard furnace E08:
Technician: measure flame current at the flame sensor. This guide reads it on the FP pads, typically 0.75 to 3.0 microamps
American Standard S9V2 installer's guide (18-CE01D1-1E-EN) (opens in a new tab) ↗
Bryant
- Bryant furnace 34:
Oxide buildup on the flame sensor
Bryant 80% variable-speed two-stage furnace troubleshooting guide (Catalog No. TG-GFB80-02) (opens in a new tab) ↗
Carrier
- Carrier furnace 14:
Oxide buildup on flame sensor
Carrier 59SC5 installation, start-up and operating instructions (opens in a new tab) ↗ - Carrier furnace 34:
Oxide buildup on flame sensor
Carrier 59SC5 installation, start-up and operating instructions (opens in a new tab) ↗
Goodman
- Goodman furnace EE0:
Flame sensor coated or oxidized
Goodman GR9S96/GD9S96 installation and operating guide (IOG-2037B) (opens in a new tab) ↗ - Goodman furnace EE4:
Technician: correct short at flame sensor or in flame sensor wiring
Goodman GR9S96/GD9S96 installation and operating guide (IOG-2037B) (opens in a new tab) ↗ - Goodman furnace EE6:
Flame sensor coated or oxidized
Goodman GR9S96/GD9S96 installation and operating guide (IOG-2037B) (opens in a new tab) ↗
Lennox
- Lennox furnace Red slow flash, green fast flash:
Low flame signal: measures below 1.5 microamps. Replace flame sense rod.
Lennox ML180UH installation and operation manual (opens in a new tab) ↗
Rheem
- Rheem furnace 11:
Flame sense rod dirty or not connected
Rheem R96V installation instructions (92-24161-124-03) (opens in a new tab) ↗ - Rheem furnace 12:
Flame sense rod needs cleaning or is not properly connected
Rheem R96V installation instructions (92-24161-124-03) (opens in a new tab) ↗ - Rheem furnace 13:
Flame sense rod dirty or not connected
Rheem R96V installation instructions (92-24161-124-03) (opens in a new tab) ↗
Trane
- Trane furnace E2.1:
Dirty flame sensor, poor grounding, sensor location or wire connections
Trane S9V2 Service Facts (S9V2-SF-2A-EN) (opens in a new tab) ↗ - Trane furnace E2.2:
Dirty flame sensor, dirty burners, poor grounding, sensor location or wire connections
Trane S9V2 Service Facts (S9V2-SF-2A-EN) (opens in a new tab) ↗ - Trane furnace E05:
Flame sensor grounded
Trane S9V2 Service Facts (S9V2-SF-2A-EN) (opens in a new tab) ↗ - Trane furnace E08:
Flame sensor location incorrect
Trane S9V2 Service Facts (S9V2-SF-2A-EN) (opens in a new tab) ↗
York
- York furnace 7 red flashes:
Dirty or faulty flame sensor
York TG9S installation manual (Johnson Controls 1083287-UIM-C-0715) (opens in a new tab) ↗ - York furnace 8 red flashes:
Dirty or faulty flame sensor
York TG9S installation manual (Johnson Controls 1083287-UIM-C-0715) (opens in a new tab) ↗ - York furnace continuous amber:
Flame sensor that needs cleaning
York TG9S installation manual (Johnson Controls 1083287-UIM-C-0715) (opens in a new tab) ↗
Search for this part
The button opens an Amazon search for the part name. It does not confirm a fit for your model, and it does not make the repair a homeowner job. Gas, venting and line-voltage work belongs to a licensed technician.
As an Amazon Associate I earn from qualifying purchases. Affiliate disclosure
Unplug the furnace or switch it off at the breaker, and shut off the gas supply where relevant, before you open any panel. Capacitors can hold a charge after power is off. Gas, electrical-panel, refrigerant and carbon-monoxide work belongs to a licensed professional. Follow the manual for your model (safety terms).