Flame sense current is below 1.5 microamps. The manual's ignition-control levels put a normal flame sense current at about 3.7 microamps DC, the low-flame warning at 1.5 microamps, and the control lockout point at 0.1 microamps DC.
Homeowner part this code names: furnace flame sensor.
Search on AmazonOpens an Amazon search for that name. Check the size against your manual. As an Amazon Associate I earn from qualifying purchases.
A continuous amber flash on a York TG9S, with no long pause, means flame current is under 1.5 microamps. The same page lists normal current at about 3.7 microamps, the warning at 1.5, and lockout at 0.1. The checks are to clean the flame sensor, check gas flow, and read the current at the flame test pad. That reading is a technician measurement. It is not a counted red code.
Likely causes
- Flame sensor that needs cleaning
- Gas flow that is not correct
Safe checks for continuous amber
- Write down that the light is amber and continuous, not a counted red code
- Techniciancheck and clean the flame sensor, check gas flow, and verify that current at the flame current test pad is greater than 1.5 microamps
Capacitors can hold a charge after the power is off. Safety terms.
When to call a pro
Call a licensed HVAC technician to clean the flame sensor and measure flame current. A continuous amber light is a warning, not one of the numbered red codes.
Email me this fix
We save your email and this page. Nothing is emailed. We'll only use your email for this request.
Request a filter and maintenance reminder
We save your email, this page, and the interval you pick. Nothing is emailed. We'll only use your email for this request.
Parts & tools for this fix
Taken from this code's causes or steps. A search link opens Amazon results and does not confirm a fit. Check the model number in the manual.
Furnace flame sensor: guide
In this code: Flame sensor that needs cleaning
Nut driver set: guide
In this code: Panels and parts on a furnace are held by hex-head screws; a nut driver grips them without stripping.
See the guide for what to look for when buying one.
Multimeter for appliance and HVAC diagnosis: guide
Technician step in this code: check and clean the flame sensor, check gas flow, and verify that current at the flame current test pad is greater than 1.5 microamps
This one is for a technician to test or replace, so we only explain it and do not link to buy it.
As an Amazon Associate I earn from qualifying purchases.Affiliate disclosure