Codes that name it
Amana
- Amana furnace EE7:
Igniter relay fault on the integrated control module
Amana and Goodman *CVC96 / *MVC96 two-stage furnace installation instructions (IOG-2015L) (opens in a new tab) ↗
Bryant
- Bryant furnace 21:
Defective control valve relay
Bryant 80% variable-speed two-stage furnace troubleshooting guide (Catalog No. TG-GFB80-02) (opens in a new tab) ↗ - Bryant furnace 45:
Control circuitry lockout. The control auto-resets after a 1-hour lockout caused by a flame-sense circuit failure, a gas-valve relay stuck open, or a software check error. Reset power to clear the lockout. Replace the control if the code repeats.
Bryant 80% variable-speed two-stage furnace troubleshooting guide (Catalog No. TG-GFB80-02) (opens in a new tab) ↗
Carrier
- Carrier furnace 21:
Stuck closed gas valve relay on control (defective control)
Carrier 59SC5 installation, start-up and operating instructions (opens in a new tab) ↗ - Carrier furnace 45:
Technician: replace the control if the status code repeats
Carrier 59SC5 installation, start-up and operating instructions (opens in a new tab) ↗
Goodman
- Goodman furnace Ear:
A2L relay fault on the furnace control board
Goodman *R9S96/*D9S96 and *R9S92 single-stage gas furnace installation instructions (IOG-2037B), 1-stage troubleshooting codes. Read 2026-11-07 (opens in a new tab) ↗ - Goodman furnace EEb:
Technician: replace integrated control board if wiring is good
Goodman GR9S96/GD9S96 installation and operating guide (IOG-2037B) (opens in a new tab) ↗ - Goodman furnace EEC:
Technician: replace integrated control board if wiring is good
Goodman GR9S96/GD9S96 installation and operating guide (IOG-2037B) (opens in a new tab) ↗ - Goodman furnace EEE:
Internal control board fault
Goodman GR9S96/GD9S96 installation and operating guide (IOG-2037B) (opens in a new tab) ↗ - Goodman furnace EEH:
Integrated control board
Goodman *R9S96/*D9S96 and *R9S92 single-stage gas furnace installation instructions (IOG-2037B), 1-stage troubleshooting codes. Read 2026-11-07 (opens in a new tab) ↗ - Goodman furnace EEJ:
Inducer relay error on the integrated control
Goodman *R9S96/*D9S96 and *R9S92 single-stage gas furnace installation instructions (IOG-2037B), 1-stage troubleshooting codes. Read 2026-11-07 (opens in a new tab) ↗ - Goodman furnace EEL:
Igniter relay fault on integrated control module
Goodman GR9S96/GD9S96 installation and operating guide (IOG-2037B) (opens in a new tab) ↗
Lennox
- Lennox furnace Board failure pattern:
Integrated control failure
Lennox ML180UH installation and operation manual (opens in a new tab) ↗
Rheem
- Rheem furnace 45:
Faulty control board (inducer relay)
Rheem R96V installation instructions (92-24161-124-03) (opens in a new tab) ↗ - Rheem furnace 46:
Faulty control board
Rheem R96V installation instructions (92-24161-124-03) (opens in a new tab) ↗ - Rheem furnace 57:
Faulty control board
Rheem R96V installation instructions (92-24161-124-03) (opens in a new tab) ↗
Trane
- Trane furnace E01:
Internal failure of the control board
Trane S9V2 Service Facts (S9V2-SF-2A-EN) (opens in a new tab) ↗ - Trane furnace E6.3:
Technician: check igniter resistance (37-70 ohms at ~75F); replace igniter or IFC as indicated
Trane S9V2 Service Facts (S9V2-SF-2A-EN) (opens in a new tab) ↗ - Trane furnace E7.1:
Technician: check for 24 VAC at gas valve with no heat call; correct wiring or replace IFC
Trane S9V2 Service Facts (S9V2-SF-2A-EN) (opens in a new tab) ↗ - Trane furnace E14:
Do not pull the control board to look for the module with power on
Trane S9V2 Service Facts S9V2-SF-2A-EN (04 Mar 2021), troubleshooting section. Read 2026-11-07 (opens in a new tab) ↗ - Trane furnace E15:
Technician: the chart's possible causes are a corrupted personality module and a faulty IFC. It does not list a filter or a gas-valve check
Trane S9V2 Service Facts S9V2-SF-2A-EN (04 Mar 2021), troubleshooting section. Read 2026-11-07 (opens in a new tab) ↗ - Trane furnace E18:
Technician: with power on, remove the 4-pin motor connector from the IFC. If the code changes to E17, verify the harness and wiring. If it does not change, replace the IFC
Trane S9V2 Service Facts S9V2-SF-2A-EN (04 Mar 2021), troubleshooting section. Read 2026-11-07 (opens in a new tab) ↗
Search for this part
The button opens an Amazon search for the part name. It does not confirm a fit for your model, and it does not make the repair a homeowner job. Gas, venting and line-voltage work belongs to a licensed technician.
As an Amazon Associate I earn from qualifying purchases. Affiliate disclosure
Unplug the furnace or switch it off at the breaker, and shut off the gas supply where relevant, before you open any panel. Capacitors can hold a charge after power is off. Gas, electrical-panel, refrigerant and carbon-monoxide work belongs to a licensed professional. Follow the manual for your model (safety terms).