Gas heating lockout. Control will NOT auto-reset.
§1Likely causes
- Mis-wired gas valve
- Stuck closed gas valve relay on control (defective control)
- Short to gas valve wire
§2Safe DIY steps
- Turn off power and wait 5 minutes to retry
- Techniciancheck gas valve wiring and the control valve relay
§3When to call a pro
Call a licensed HVAC technician: always; this lockout does not clear on its own and points to a gas valve circuit fault.
Find a local HVAC pro →§4Other Carrier codes
Limit circuit lockout: a limit or flame rollout switch was open longer than 3 minutes. Control auto-resets after 3 hours (see code 33).
14CarrierIgnition lockout: system failed to ignite gas and prove flame in 4 attempts. Control auto-resets after 3 hours (see code 34).
22CarrierAbnormal flame-proving signal: flame is proved while the gas valve is de-energized. Inducer runs until the fault is cleared.
23CarrierPressure switch did not open.
31CarrierLow (LPS) or high (HPS) pressure switch did not close or reopened.
24CarrierSecondary voltage (24 V) fuse is open.