Limit circuit lockout: a limit or flame rollout switch was open longer than 3 minutes. Control auto-resets after 3 hours (see code 33).
§1Likely causes
- Dirty filter or restricted duct system
- Restricted vent or improper vent sizing
- Loose blower wheel
- Defective blower motor or capacitor
- Defective switch or connections
- Inadequate combustion air supply (flame rollout switch open)
- Excessive wind
§2Safe DIY steps
- Turn off power and check/replace a dirty air filter
- Make sure return and supply grilles are open and unobstructed
- Techniciancheck vent sizing and restrictions, blower wheel, blower motor/capacitor, switches and connections
- Technicianflame rollout switch requires manual reset only after the cause is found
§3When to call a pro
Call a licensed HVAC technician: if the furnace locks out again after replacing the filter, or if a rollout switch has tripped.
Find a local HVAC pro →§4Other Carrier codes
Ignition lockout: system failed to ignite gas and prove flame in 4 attempts. Control auto-resets after 3 hours (see code 34).
21CarrierGas heating lockout. Control will NOT auto-reset.
22CarrierAbnormal flame-proving signal: flame is proved while the gas valve is de-energized. Inducer runs until the fault is cleared.
23CarrierPressure switch did not open.
31CarrierLow (LPS) or high (HPS) pressure switch did not close or reopened.
24CarrierSecondary voltage (24 V) fuse is open.