Codes that name it
Amana
- Amana furnace EE3:
Improper circulator blower speed or a failed circulator blower motor
Amana and Goodman *CVC96 / *MVC96 two-stage furnace installation instructions (IOG-2015L) (opens in a new tab) ↗ - Amana furnace EEd:
Circulator blower speed or a failed blower motor
Amana and Goodman *CVC96 / *MVC96 two-stage furnace installation instructions (IOG-2015L) (opens in a new tab) ↗
Bryant
- Bryant furnace 15:
Blower motor lockout. The blower failed to reach 250 RPM, or failed to communicate, within 30 seconds after being turned on, in two successive heating cycles. The control auto-resets after 3 hours. The chart says to see status code 41.
Bryant 80% variable-speed two-stage furnace troubleshooting guide (Catalog No. TG-GFB80-02) (opens in a new tab) ↗ - Bryant furnace 33:
Loose blower wheel
Bryant 80% variable-speed two-stage furnace troubleshooting guide (Catalog No. TG-GFB80-02) (opens in a new tab) ↗ - Bryant furnace 41:
Blower motor fault. The blower failed to reach 250 RPM, or failed to communicate, within 30 seconds after being turned on or within 10 seconds during steady-state operation.
Bryant 80% variable-speed two-stage furnace troubleshooting guide (Catalog No. TG-GFB80-02) (opens in a new tab) ↗
Carrier
Goodman
- Goodman AC / heat pump b0:
Indoor blower motor problem
Goodman service manual RS6200007 r27, PCBHR104 unitary diagnostic codes (opens in a new tab) ↗ - Goodman furnace EbL:
Blower motor not operating correctly, or the wrong speed setting
Goodman *R9S96/*D9S96 and *R9S92 single-stage gas furnace installation instructions (IOG-2037B), 1-stage troubleshooting codes. Read 2026-11-07 (opens in a new tab) ↗ - Goodman furnace EbU:
Loose wiring to or from the blower motor
Goodman *R9S96/*D9S96 and *R9S92 single-stage gas furnace installation instructions (IOG-2037B), 1-stage troubleshooting codes. Read 2026-11-07 (opens in a new tab) ↗ - Goodman furnace EE3:
Improper circulator blower speed or failed circulator blower motor
Goodman GR9S96/GD9S96 installation and operating guide (IOG-2037B) (opens in a new tab) ↗
Rheem
- Rheem furnace d6:
Blower motor was replaced with the wrong horsepower
Rheem (-)96V series installation instructions 92-24161-124-03, Table 20 R96V fault codes. Read 2026-11-07 (opens in a new tab) ↗
Trane
- Trane furnace E04:
Dirty filters or blower wheel
Trane S9V2 Service Facts (S9V2-SF-2A-EN) (opens in a new tab) ↗ - Trane furnace E13:
Blower motor horsepower does not match the nameplate
Trane S9V2 Service Facts S9V2-SF-2A-EN (04 Mar 2021), troubleshooting section. Read 2026-11-07 (opens in a new tab) ↗
Search for this part
The button opens an Amazon search for the part name. It does not confirm a fit for your model, and it does not make the repair a homeowner job. Gas, venting and line-voltage work belongs to a licensed technician.
As an Amazon Associate I earn from qualifying purchases. Affiliate disclosure
Unplug the furnace or switch it off at the breaker, and shut off the gas supply where relevant, before you open any panel. Capacitors can hold a charge after power is off. Gas, electrical-panel, refrigerant and carbon-monoxide work belongs to a licensed professional. Follow the manual for your model (safety terms).