Bryant 15: Blower motor lockout

Source: Bryant manual (PDF) (opens in a new tab) ↗ · Updated

Status code15Bryant
What does Bryant 15 mean?

Blower motor lockout. The blower failed to reach 250 RPM, or failed to communicate, within 30 seconds after being turned on, in two successive heating cycles. The control auto-resets after 3 hours. The chart says to see status code 41.

How it shows: Amber LED on a Bryant 80% two-stage variable-speed furnace (troubleshooting guide TG-GFB80-02). Short flashes are the first digit and long flashes are the second. Code 15 is 1 short and 5 long

Bryant 15 is the blower-motor lockout on the 80% two-stage chart, not the fault while the blower is still being watched. The blower failed to reach 250 RPM, or failed to communicate, within 30 seconds after it was turned on, and that happened on two heating cycles in a row. The control auto-resets after 3 hours and says to see code 41. Code 41 is the fault itself, including a miss during steady running. Code 12 is only the 90-second blower run after power-up.

Likely causes

  • Blower did not reach 250 RPM within 30 seconds of being turned on, twice in a row during heating
  • Blower did not communicate within 30 seconds of being turned on, twice in a row during heating

Safe checks for 15

  1. Count 1 short flash and 5 long flashes. The 3-hour auto-reset is not a repair
  2. Technicianuse status code 41, which this lockout points to, for the blower, the wiring, and the furnace control
Safety firstIf you smell gas, do not touch any electrical switch or use a phone in the building; leave immediately and call your gas supplier from outside. Turn off electrical power at the furnace switch or breaker before opening any panel, and never bypass or jumper a limit, rollout or pressure switch. Gas valve, burner, venting, wiring and control-board work should be done by a licensed HVAC technician.

Capacitors can hold a charge after the power is off. Safety terms.

When to call a pro

Call a licensed HVAC technician if 15 is stored. Do not keep cycling power to clear the 3-hour timer.

Find a Bryant dealer (official locator, opens in a new tab) ↗

Email me this fix

We save your email and this page. Nothing is emailed. We'll only use your email for this request.

Privacy. Deletion requests go to the address on that page.

Request a filter and maintenance reminder

We save your email, this page, and the interval you pick. Nothing is emailed. We'll only use your email for this request.

Privacy. Deletion requests go to the address on that page.

Parts & tools for this fix

Taken from this code's causes or steps. A search link opens Amazon results and does not confirm a fit. Check the model number in the manual.

Furnace blower (circulator) motor: guide

In this code: Blower did not reach 250 RPM within 30 seconds of being turned on, twice in a row during heating

This one is for a technician to test or replace, so we only explain it and do not link to buy it.

Related Bryant codes

All Bryant codes →Browse every code