Affiliate links may earn us a commission. As an Amazon Associate I earn from qualifying purchases. Affiliate disclosure

Bryant 14: Ignition lockout

Source: Bryant manual (PDF) (opens in a new tab) ↗ · Updated

Status code14Bryant
What does Bryant 14 mean?

Ignition lockout. The system failed to ignite gas and prove flame in 4 attempts. The control auto-resets after 3 hours. The manual says to see status code 34.

Homeowner part this code names: furnace hot surface igniter.

Search on Amazon

Opens an Amazon search for that name. Check the size against your manual. As an Amazon Associate I earn from qualifying purchases.

How it shows: Amber status LED on a Bryant 926TB: short flashes, then long flashes. Code 14 is 1 short flash and 4 long flashes

Bryant 926TB code 14 is ignition lockout. Count 1 short flash and 4 long flashes. The guide says the furnace failed to ignite gas and prove flame in 4 attempts, then auto-resets after 3 hours, and says to see code 34. The sequence in the same manual warms the hot-surface igniter for 17 seconds and then allows a 2-second proving window. It also says the control must be grounded or it will lock out. Resetting the 3-hour timer is not a repair.

Likely causes

  • Gas did not ignite and flame was not proved in 4 attempts

Safe checks for 14

  1. Count 1 short flash and 4 long flashes. The same manual's sequence says the hot-surface igniter warms up for 17 seconds, then a 2-second flame-proving window follows. Failed trials repeat, then the control goes to ignition lockout
  2. The sequence says lockout resets after three hours, or when 115 V or 24 V power to the control is interrupted. Resetting is not a repair
  3. The sequence also says the furnace control must be grounded or it will lock out
  4. Technicianfollow status code 34, which code 14 points to
Safety firstIf you smell gas, do not touch any electrical switch or use a phone in the building; leave immediately and call your gas supplier from outside. Turn off electrical power at the furnace switch or breaker before opening any panel, and never bypass or jumper a limit, rollout or pressure switch. Gas valve, burner, venting, wiring and control-board work should be done by a licensed HVAC technician.

Capacitors can hold a charge after the power is off. Safety terms.

When to call a pro

Call a licensed HVAC technician if 14 returns after the 3-hour reset. Do not jumper the gas valve.

Find a Bryant dealer (official locator, opens in a new tab) ↗

Email me this fix

We save your email and this page. Nothing is emailed. We'll only use your email for this request.

Privacy. Deletion requests go to the address on that page.

Request a filter and maintenance reminder

We save your email, this page, and the interval you pick. Nothing is emailed. We'll only use your email for this request.

Privacy. Deletion requests go to the address on that page.

Parts & tools for this fix

Taken from this code's causes or steps. A search link opens Amazon results and does not confirm a fit. Check the model number in the manual.

Furnace hot surface igniter: guide

In this code: Count 1 short flash and 4 long flashes. The same manual's sequence says the hot-surface igniter warms up for 17 seconds, then a 2-second flame-proving window follows.…

Nut driver set: guide

In this code: Panels and parts on a furnace are held by hex-head screws; a nut driver grips them without stripping.

See the guide for what to look for when buying one.

As an Amazon Associate I earn from qualifying purchases.Affiliate disclosure

Related Bryant codes

All Bryant codes →Browse every code