Bryant 41: Blower motor fault

Source: Bryant manual (PDF) (opens in a new tab) ↗ · Updated

Status code41Bryant
What does Bryant 41 mean?

Blower motor fault. The blower failed to reach 250 RPM, or failed to communicate, within 30 seconds after being turned on or within 10 seconds during steady-state operation.

How it shows: Amber LED on a Bryant 80% two-stage variable-speed furnace (troubleshooting guide TG-GFB80-02). Short flashes are the first digit and long flashes are the second. Code 41 is 4 short and 1 long

Bryant 41 is the blower motor fault, not the lockout. The blower failed to reach 250 RPM or failed to communicate within 30 seconds after being turned on, or within 10 seconds during steady running. Lockout 15 is what the chart stores after that miss happens on two heating cycles in a row, and 15 says to see 41. The component-test row for 41 says to check the blower, the wiring, and the furnace control.

Likely causes

  • Blower did not reach 250 RPM within 30 seconds of being turned on
  • Blower did not communicate within 30 seconds of being turned on
  • During steady running, the blower missed 250 RPM or communication within 10 seconds

Safe checks for 41

  1. Count 4 short flashes and 1 long flash. If this happened on two heating cycles in a row, the chart stores lockout 15
  2. Technicianthe component-test line for code 41 says to check the blower, the wiring, and the furnace control
Safety firstIf you smell gas, do not touch any electrical switch or use a phone in the building; leave immediately and call your gas supplier from outside. Turn off electrical power at the furnace switch or breaker before opening any panel, and never bypass or jumper a limit, rollout or pressure switch. Gas valve, burner, venting, wiring and control-board work should be done by a licensed HVAC technician.

Capacitors can hold a charge after the power is off. Safety terms.

When to call a pro

Call a licensed HVAC technician. Blower RPM and communication checks are not a homeowner meter job.

Find a Bryant dealer (official locator, opens in a new tab) ↗

Email me this fix

We save your email and this page. Nothing is emailed. We'll only use your email for this request.

Privacy. Deletion requests go to the address on that page.

Request a filter and maintenance reminder

We save your email, this page, and the interval you pick. Nothing is emailed. We'll only use your email for this request.

Privacy. Deletion requests go to the address on that page.

Parts & tools for this fix

Taken from this code's causes or steps. A search link opens Amazon results and does not confirm a fit. Check the model number in the manual.

Furnace blower (circulator) motor: guide

In this code: Blower did not reach 250 RPM within 30 seconds of being turned on

This one is for a technician to test or replace, so we only explain it and do not link to buy it.

Furnace control board and low-voltage fuse: guide

In this code: Parts list for this code: Furnace control board

This one is for a technician to test or replace, so we only explain it and do not link to buy it.

Related Bryant codes

All Bryant codes →Browse every code