Bryant 42: Inducer motor fault on a Bryant 987MA modulating furnace

Source: Bryant manual (PDF) (opens in a new tab) ↗ · Updated

Status code42Bryant
What does Bryant 42 mean?

Inducer motor fault on a Bryant 987MA modulating furnace. The inducer has not started within 20 seconds after a call for heat, the inducer RPM is outside its valid range, or the RPM signal was lost for 5 seconds during operation.

How it shows: Amber LED on a Bryant 987MA Series A modulating furnace (Form 987MA-01T). Short flashes are the first digit and long flashes are the second. Code 42 is 4 short and 2 long

Bryant 42 is an inducer motor fault on the 987MA Series A modulating chart. The inducer did not start within 20 seconds after a call for heat, the RPM is outside its valid range, or the RPM signal was lost for 5 seconds while running. The chart lists vent sizing, a restricted vent, and a failed inducer. The 80% two-stage chart has no code 42. Code 41 on that chart is the blower, not the inducer.

Likely causes

  • Inducer did not start within 20 seconds of a call for heat
  • Inducer RPM outside its valid range, or the RPM signal lost for 5 seconds
  • Vent sizing is wrong, or the vent is restricted
  • Failed inducer motor

Safe checks for 42

  1. Look at the outdoor intake and exhaust terminations for a blockage. Leave the pipes connected
  2. Techniciancheck vent sizing, a restricted vent, and the inducer motor. This code is not blower fault 41
Safety firstIf you smell gas, do not touch any electrical switch or use a phone in the building; leave immediately and call your gas supplier from outside. Turn off electrical power at the furnace switch or breaker before opening any panel, and never bypass or jumper a limit, rollout or pressure switch. Gas valve, burner, venting, wiring and control-board work should be done by a licensed HVAC technician.

Capacitors can hold a charge after the power is off. Safety terms.

When to call a pro

Call a licensed HVAC technician if the terminations are clear and 42 remains. Inducer replacement is not a homeowner job.

Find a Bryant dealer (official locator, opens in a new tab) ↗

Email me this fix

We save your email and this page. Nothing is emailed. We'll only use your email for this request.

Privacy. Deletion requests go to the address on that page.

Request a filter and maintenance reminder

We save your email, this page, and the interval you pick. Nothing is emailed. We'll only use your email for this request.

Privacy. Deletion requests go to the address on that page.

Parts & tools for this fix

Taken from this code's causes or steps. A search link opens Amazon results and does not confirm a fit. Check the model number in the manual.

Furnace inducer (draft) motor: guide

In this code: Inducer did not start within 20 seconds of a call for heat

This one is for a technician to test or replace, so we only explain it and do not link to buy it.

Furnace blower (circulator) motor: guide

Technician step in this code: check vent sizing, a restricted vent, and the inducer motor. This code is not blower fault 41