Bryant 43: Low-heat pressure switch is open while the high-heat pressure switch

Source: Bryant manual (PDF) (opens in a new tab) ↗ · Updated

Status code43Bryant
What does Bryant 43 mean?

Low-heat pressure switch is open while the high-heat pressure switch is closed. The chart says to check the pressure tubing, low inlet gas pressure if a low-gas-pressure switch is used, mis-wired switches, and a low-heat switch stuck open.

Homeowner part this code names: furnace pressure switch hose.

Search on Amazon

Opens an Amazon search for that name. Check the size against your manual. As an Amazon Associate I earn from qualifying purchases.

How it shows: Amber LED on a Bryant 80% two-stage variable-speed furnace (troubleshooting guide TG-GFB80-02). Short flashes are the first digit and long flashes are the second. Code 43 is 4 short and 3 long

Bryant 43 means the low-heat pressure switch is open while the high-heat pressure switch is closed. The chart lists disconnected or obstructed pressure tubing, low inlet gas pressure if an LGPS is used, mis-wired pressure switches, and a low-heat switch stuck open. It is not code 32, which is the low-heat switch that did not close on its own, and it is not code 23, which is a switch that did not open.

Likely causes

  • Disconnected or obstructed pressure tubing
  • Low inlet gas pressure, if a low-gas-pressure switch is used
  • Mis-wired pressure switches
  • Low-heat pressure switch stuck open

Safe checks for 43

  1. Count 4 short flashes and 3 long flashes. Do not swap the pressure-switch hoses to see what happens
  2. Techniciancheck tubing, switch wiring, and the low-heat switch. Gas pressure, if an LGPS is used, is part of that check
Safety firstIf you smell gas, do not touch any electrical switch or use a phone in the building; leave immediately and call your gas supplier from outside. Turn off electrical power at the furnace switch or breaker before opening any panel, and never bypass or jumper a limit, rollout or pressure switch. Gas valve, burner, venting, wiring and control-board work should be done by a licensed HVAC technician.

Capacitors can hold a charge after the power is off. Safety terms.

When to call a pro

Call a licensed HVAC technician. Two pressure switches disagreeing is not a vent-cap cleaning.

Find a Bryant dealer (official locator, opens in a new tab) ↗

Email me this fix

We save your email and this page. Nothing is emailed. We'll only use your email for this request.

Privacy. Deletion requests go to the address on that page.

Request a filter and maintenance reminder

We save your email, this page, and the interval you pick. Nothing is emailed. We'll only use your email for this request.

Privacy. Deletion requests go to the address on that page.

Parts & tools for this fix

Taken from this code's causes or steps. A search link opens Amazon results and does not confirm a fit. Check the model number in the manual.

Furnace pressure switch hose: guide

In this code: Disconnected or obstructed pressure tubing

See the guide for what to look for when buying one.

Furnace pressure switch: guide

In this code: Low inlet gas pressure, if a low-gas-pressure switch is used

This one is for a technician to test or replace, so we only explain it and do not link to buy it.