Codes that name it
Amana
- Amana furnace EE2:
Pressure switch hose blocked, pinched, or connected improperly
Amana and Goodman *CVC96 / *MVC96 two-stage furnace installation instructions (IOG-2015L) (opens in a new tab) ↗ - Amana furnace EE9:
Pressure switch hose blocked, pinched, or needing repair
Amana and Goodman *CVC96 / *MVC96 two-stage furnace installation instructions (IOG-2015L) (opens in a new tab) ↗
American Standard
- American Standard furnace E3.2:
The install steps say pressure-switch tubing must rise so condensed flue gas does not enter the switch
American Standard S9V2 installer's guide (18-CE01D1-1E-EN) (opens in a new tab) ↗ - American Standard furnace E3.4:
Technician: check the 2nd stage pressure switch, tubing and inducer. Tubing must rise so condensate does not enter the switch
American Standard S9V2 installer's guide (18-CE01D1-1E-EN) (opens in a new tab) ↗
Bryant
- Bryant furnace 23:
Obstructed pressure tubing
Bryant 80% variable-speed two-stage furnace troubleshooting guide (Catalog No. TG-GFB80-02) (opens in a new tab) ↗ - Bryant furnace 32:
Disconnected or obstructed pressure tubing
Bryant 80% variable-speed two-stage furnace troubleshooting guide (Catalog No. TG-GFB80-02) (opens in a new tab) ↗ - Bryant furnace 43:
Disconnected or obstructed pressure tubing
Bryant 80% variable-speed two-stage furnace troubleshooting guide (Catalog No. TG-GFB80-02) (opens in a new tab) ↗
Carrier
- Carrier furnace 23:
Obstructed pressure tubing
Carrier 59SC5 installation, start-up and operating instructions (opens in a new tab) ↗ - Carrier furnace 31:
Disconnected or obstructed pressure tubing
Carrier 59SC5 installation, start-up and operating instructions (opens in a new tab) ↗
Goodman
- Goodman furnace EE0:
Technician: check front cover pressure switch operation and drainage (hose, wiring, contacts)
Goodman GR9S96/GD9S96 installation and operating guide (IOG-2037B) (opens in a new tab) ↗ - Goodman furnace EE2:
Pressure switch hose blocked, pinched or connected improperly
Goodman GR9S96/GD9S96 installation and operating guide (IOG-2037B) (opens in a new tab) ↗
Rheem
- Rheem furnace 45:
Disconnected, blocked, split or cut pressure switch hoses
Rheem R96V installation instructions (92-24161-124-03) (opens in a new tab) ↗ - Rheem furnace 46:
Damaged pressure switch hoses
Rheem R96V installation instructions (92-24161-124-03) (opens in a new tab) ↗ - Rheem furnace 57:
Damaged pressure switch hoses
Rheem R96V installation instructions (92-24161-124-03) (opens in a new tab) ↗
Trane
- Trane furnace E3.2:
Obstructed pressure switch hose or flue piping, or incorrect vent size
Trane S9V2 Service Facts (S9V2-SF-2A-EN) (opens in a new tab) ↗ - Trane furnace E3.4:
Obstructed pressure switch hose or flue piping, or incorrect vent size
Trane S9V2 Service Facts (S9V2-SF-2A-EN) (opens in a new tab) ↗
York
- York furnace 3 red flashes:
Broken pressure switch hose
York TG9S installation manual (Johnson Controls 1083287-UIM-C-0715) (opens in a new tab) ↗
Search for this part
The button opens an Amazon search for the part name. It does not confirm a fit for your model, and it does not make the repair a homeowner job. Gas, venting and line-voltage work belongs to a licensed technician.
As an Amazon Associate I earn from qualifying purchases. Affiliate disclosure
Unplug the furnace or switch it off at the breaker, and shut off the gas supply where relevant, before you open any panel. Capacitors can hold a charge after power is off. Gas, electrical-panel, refrigerant and carbon-monoxide work belongs to a licensed professional. Follow the manual for your model (safety terms).