Status codeEE2Goodman
What it means
Pressure switch circuit is not closed.
Call a profurnace
How it shows: Shown on the control board 7-segment display: EE2 (induced draft blower runs, furnace does not light)
§1Likely causes
- Pressure switch hose blocked, pinched or connected improperly
- Blocked flue and/or inlet air pipe
- Blocked drain system
- Weak induced draft blower
- Incorrect pressure switch set point or malfunctioning switch contacts
- Loose or improperly connected wiring
§2Safe DIY steps
- Check the outdoor flue and intake terminations for blockage (snow, debris, nests)
- Technicianinspect the pressure switch hose and repair or replace if necessary
- Technicianinspect flue/inlet piping length, elbows and termination
- Techniciancheck the drain system
- Techniciancheck induced draft blower performance and pressure switch operation
- Techniciantighten or correct wiring connections
Safety firstIf you smell gas, do not touch any electrical switch or use a phone in the building; leave immediately and call your gas supplier from outside. Turn off electrical power at the furnace switch or breaker before opening any panel, and never bypass or jumper a limit, rollout or pressure switch. Gas valve, burner, venting, wiring and control-board work should be done by a licensed HVAC technician.
§3When to call a pro
Call a licensed HVAC technician: if the vent terminations are clear and the code persists.
Find a local HVAC pro →§4Other Goodman codes
E11Goodman
Open rollout switch.
E10GoodmanGrounding fault / poor neutral connection.
EE1GoodmanPressure switch circuit is closed at the start of the heating cycle.
EE0GoodmanFurnace lockout after too many ignition retries (3 total): flame failed to establish or was lost after establishment.
EE3GoodmanPrimary limit circuit is open.
EE4GoodmanFlame sensed with no call for heat.