Status codeE3.2Trane
What it means
Open pressure switch, 1st stage: PS1 is open when it should be closed.
Call a profurnace
How it shows: 7-segment display alternates with mode: E3.2
§1Likely causes
- Obstructed pressure switch hose or flue piping, or incorrect vent size
- Wind gusts
- Inducer motor not running
- PS1 not oriented correctly
- Faulty pressure switch
§2Safe DIY steps
- Check outdoor vent and intake terminations for blockage
- Techniciancheck PS hose, flue piping and vent size
- Techniciancheck inducer voltage and operation; replace inducer assembly or pressure switch as indicated
Safety firstIf you smell gas, do not touch any electrical switch or use a phone in the building; leave immediately and call your gas supplier from outside. Turn off electrical power at the furnace switch or breaker before opening any panel, and never bypass or jumper a limit, rollout or pressure switch. Gas valve, burner, venting, wiring and control-board work should be done by a licensed HVAC technician.
§3When to call a pro
Call a licensed HVAC technician: if terminations are clear and the code persists.
Find a local HVAC pro →§4Other Trane codes