American Standard E3.2: Open pressure switch, 1st stage

Source: American Standard manual (PDF) (opens in a new tab) ↗ · Updated

Status codeE3.2American Standard
What does American Standard E3.2 mean?

Open pressure switch, 1st stage.

Homeowner part this code names: furnace pressure switch hose.

Search on Amazon

Opens an Amazon search for that name. Check the size against your manual. As an Amazon Associate I earn from qualifying purchases.

How it shows: 7-segment display on an American Standard S9V2 two-stage variable-speed furnace: E3.2

American Standard S9V2 E3.2 is an open 1st stage pressure switch. In the heating sequence the inducer starts and pressure switch 1 is supposed to close. The guide also says that if a thermal limit is open, 24 volts will not be present at either pressure switch, and that pressure-switch tubing has to rise so flue condensate does not run into the switch. E3.4 is the open 2nd stage switch, and low stage can still run on that one.

Likely causes

  • 1st stage pressure switch did not close

Safe checks for E3.2

  1. The heating sequence says the inducer starts and pressure switch 1 should then close. If a thermal limit is open, the guide says 24 VAC will not be present at either pressure switch
  2. The install steps say pressure-switch tubing must rise so condensed flue gas does not enter the switch
  3. Techniciancheck the 1st stage pressure switch, its tubing and the inducer
Safety firstIf you smell gas, do not touch any electrical switch or use a phone in the building; leave immediately and call your gas supplier from outside. Turn off electrical power at the furnace switch or breaker before opening any panel, and never bypass or jumper a limit, rollout or pressure switch. Gas valve, burner, venting, wiring and control-board work should be done by a licensed HVAC technician.

Capacitors can hold a charge after the power is off. Safety terms.

When to call a pro

Call a licensed HVAC technician if E3.2 remains. First-stage heat will not prove until that switch closes.

Find a American Standard dealer (official locator, opens in a new tab) ↗

Email me this fix

We save your email and this page. Nothing is emailed. We'll only use your email for this request.

Privacy. Deletion requests go to the address on that page.

Request a filter and maintenance reminder

We save your email, this page, and the interval you pick. Nothing is emailed. We'll only use your email for this request.

Privacy. Deletion requests go to the address on that page.

Parts & tools for this fix

Taken from this code's causes or steps. A search link opens Amazon results and does not confirm a fit. Check the model number in the manual.

Furnace pressure switch: guide

In this code: 1st stage pressure switch did not close

This one is for a technician to test or replace, so we only explain it and do not link to buy it.

Furnace inducer (draft) motor: guide

In this code: The heating sequence says the inducer starts and pressure switch 1 should then close. If a thermal limit is open, the guide says 24 VAC will not be present at either…

This one is for a technician to test or replace, so we only explain it and do not link to buy it.

High limit and rollout switches: guide

In this code: The heating sequence says the inducer starts and pressure switch 1 should then close. If a thermal limit is open, the guide says 24 VAC will not be present at either…

A safety device: we explain it but do not link to buy one.

As an Amazon Associate I earn from qualifying purchases.Affiliate disclosure

Related American Standard codes

All American Standard codes →Browse every code