Open pressure switch, 2nd stage.
American Standard S9V2 E3.4 is an open 2nd stage pressure switch. The sequence gives PS2 45 seconds to close. If it does not, the furnace records the open switch and stays in 1st stage. On the third miss in the same heat call, 2nd stage locks out until the thermostat call ends or power is cycled. The house can still have low-stage heat. E3.2 is the 1st stage switch, which stops ignition.
Likely causes
- 2nd stage pressure switch did not close
Safe checks for E3.4
- The 2nd stage sequence says if pressure switch 2 does not close within 45 seconds, the furnace declares a PS2 open error and keeps running in 1st stage
- If PS2 fails on the third attempt in the same heating call, the guide says 2nd stage locks out until the heat call is removed or power is cycled
- Techniciancheck the 2nd stage pressure switch, tubing and inducer. Tubing must rise so condensate does not enter the switch
Capacitors can hold a charge after the power is off. Safety terms.
When to call a pro
Call a licensed HVAC technician if the furnace will heat on low stage but never steps up, and E3.4 is stored.
Find a American Standard dealer (official locator, opens in a new tab) ↗Email me this fix
We save your email and this page. Nothing is emailed. We'll only use your email for this request.
Request a filter and maintenance reminder
We save your email, this page, and the interval you pick. Nothing is emailed. We'll only use your email for this request.
Parts & tools for this fix
Taken from this code's causes or steps. A search link opens Amazon results and does not confirm a fit. Check the model number in the manual.
Furnace pressure switch hose: guide
Technician step in this code: check the 2nd stage pressure switch, tubing and inducer. Tubing must rise so condensate does not enter the switch
Furnace pressure switch: guide
In this code: 2nd stage pressure switch did not close
This one is for a technician to test or replace, so we only explain it and do not link to buy it.
Furnace inducer (draft) motor: guide
Technician step in this code: check the 2nd stage pressure switch, tubing and inducer. Tubing must rise so condensate does not enter the switch
This one is for a technician to test or replace, so we only explain it and do not link to buy it.