Bryant 33: Limit circuit fault

Source: Bryant manual (PDF) (opens in a new tab) ↗ · Updated

Status code33Bryant
What does Bryant 33 mean?

Limit circuit fault. A limit, draft safeguard, flame rollout, or blocked-vent switch is open, or the furnace is in high-heat only after two successive low-heat limit trips. The blower runs for 4 minutes or until the switch remakes, whichever is longer. Open longer than 3 minutes becomes lockout 13.

Homeowner part this code names: furnace air filter.

Search on Amazon

Opens an Amazon search for that name. Check the size against your manual. As an Amazon Associate I earn from qualifying purchases.

How it shows: Amber LED on a Bryant 80% two-stage variable-speed furnace (troubleshooting guide TG-GFB80-02). Short flashes are the first digit and long flashes are the second. Code 33 is 3 short and 3 long

Bryant 33 on the 80% two-stage chart is the limit circuit fault while a limit, draft safeguard, flame rollout, or blocked-vent switch is open, or while the furnace is locked into high heat after two low-heat limit trips. The blower runs 4 minutes or until the switch remakes. Open longer than 3 minutes becomes lockout 13. The flame rollout switch needs a manual reset. A dirty filter is on this list. The 926TB install manual points its own lockout 13 at a status code 33, and that service-label figure is not copied here.

Same characters, different appliance: Bryant 33 on an AC / heat pump is a different fault. Bryant AC / heat pump 33.

Likely causes

  • Dirty filter or restricted duct system
  • Restricted vent or improper vent sizing
  • Loose blower wheel
  • Defective switch or connections
  • Excessive wind
  • Inadequate combustion air, if the flame rollout switch is open

Safe checks for 33

  1. Turn off power and check a dirty air filter. Open return and supply grilles that are blocked
  2. If a rollout switch has opened, leave the furnace off. The chart says the flame rollout switch requires a manual reset
  3. Techniciancheck the vent, the blower wheel, the switches, and combustion air before anyone resets a rollout switch
Safety firstIf you smell gas, do not touch any electrical switch or use a phone in the building; leave immediately and call your gas supplier from outside. Turn off electrical power at the furnace switch or breaker before opening any panel, and never bypass or jumper a limit, rollout or pressure switch. Gas valve, burner, venting, wiring and control-board work should be done by a licensed HVAC technician.

Capacitors can hold a charge after the power is off. Safety terms.

When to call a pro

Call a licensed HVAC technician if 33 returns after a filter change, or if a rollout switch opened. The 926TB install manual also points lockout 13 at a code 33. That service-label figure is not the list on this page. This list is TG-GFB80-02.

Find a Bryant dealer (official locator, opens in a new tab) ↗

Email me this fix

We save your email and this page. Nothing is emailed. We'll only use your email for this request.

Privacy. Deletion requests go to the address on that page.

Request a filter and maintenance reminder

We save your email, this page, and the interval you pick. Nothing is emailed. We'll only use your email for this request.

Privacy. Deletion requests go to the address on that page.

Parts & tools for this fix

Taken from this code's causes or steps. A search link opens Amazon results and does not confirm a fit. Check the model number in the manual.

Furnace blower (circulator) motor: guide

In this code: Loose blower wheel

This one is for a technician to test or replace, so we only explain it and do not link to buy it.

High limit and rollout switches: guide

In this code: Inadequate combustion air, if the flame rollout switch is open

A safety device: we explain it but do not link to buy one.

As an Amazon Associate I earn from qualifying purchases.Affiliate disclosure

Related Bryant codes

All Bryant codes →Browse every code