The main limit switch has opened and stayed open for more than five minutes. The manual says this is usually a failed blower motor or blower wheel. The control is in a hard lockout. Power has to be cycled off and on only after the problem is corrected.
York TG9S 11 red flashes means the main limit stayed open more than five minutes. The manual says that is usually a failed blower motor or blower wheel, and it is a hard lockout. Power is cycled only after the blower problem is corrected. It is the next step after 4 red flashes when the limit does not reclose. The dirty-filter check is on 4 red flashes, not on this hard lockout.
Likely causes
- Failed blower motor
- Failed blower wheel
Safe checks for 11 red flashes
- Turn the furnace off. Cycling the breaker before the blower problem is fixed only repeats the lockout
- This code follows the 4 red flash limit fault when the limit stays open for more than five minutes
- Techniciancheck the blower motor and the blower wheel
Capacitors can hold a charge after the power is off. Safety terms.
When to call a pro
Call a licensed HVAC technician. Eleven red flashes means the limit stayed open long enough that the control treats the blower as failed.
Email me this fix
We save your email and this page. Nothing is emailed. We'll only use your email for this request.
Request a filter and maintenance reminder
We save your email, this page, and the interval you pick. Nothing is emailed. We'll only use your email for this request.
Parts & tools for this fix
Taken from this code's causes or steps. A search link opens Amazon results and does not confirm a fit. Check the model number in the manual.
Furnace blower (circulator) motor: guide
In this code: Failed blower motor
This one is for a technician to test or replace, so we only explain it and do not link to buy it.
High limit and rollout switches: guide
In this code: This code follows the 4 red flash limit fault when the limit stays open for more than five minutes
A safety device: we explain it but do not link to buy one.