The pressure switch is closed when it should be open. The control checks that the contacts are open at the start of each heat cycle and will not continue ignition if they are already closed.
York TG9S 2 red flashes means the pressure switch is already closed when the heat cycle starts. The control will not continue ignition. The manual names a faulty pressure switch or miswiring, and it says never to adjust a pressure switch so the furnace will run. Blocked vent and a broken hose are the 3 red flash list, not this one.
Likely causes
- A faulty pressure switch
- Miswiring of the pressure switch
Safe checks for 2 red flashes
- Write down the 2 red flashes before power is removed
- Techniciancheck for a faulty pressure switch or miswiring. The manual says never to adjust a pressure switch to allow furnace operation
Capacitors can hold a charge after the power is off. Safety terms.
When to call a pro
Call a licensed HVAC technician if 2 red flashes return. This is a switch that is closed too early, not a blocked vent.