Circuit board failure or control wired incorrectly.
§1Likely causes
- Integrated control failure
- Control wired incorrectly
§2Safe DIY steps
- Reset the control by turning main power off and on
- Techniciancheck wiring and replace control if needed
§3When to call a pro
Call a licensed HVAC technician: if the pattern returns after a power reset.
Find a local HVAC pro →§4Other Lennox codes
Improper main ground, OR line voltage below 90 volts. Control will not respond to a heat call until voltage rises above 95 volts.
Alternating slow flashLennoxWatchguard 1 hour: burners failed to ignite or lost flame 5 times during a single heating demand.
Red fast flash, green slow flashLennoxMain power polarity reversed. Switch line and neutral.
Red off, green slow flashLennoxPressure prove switch open, OR blocked inlet/exhaust vent, OR pressure switch closed before the combustion air inducer started.
Red on, green slow flashLennoxRollout switch open, OR 12-pin connector improperly attached.
Red slow flash, green fast flashLennoxLow flame signal: measures below 1.5 microamps. Replace flame sense rod.