Rollout switch open, OR 12-pin connector improperly attached.
§1Likely causes
- Rollout switch open
- 12-pin connector improperly attached
§2Safe DIY steps
- Technicianfind the cause of rollout before resetting; check the 12-pin connector
§3When to call a pro
Call a licensed HVAC technician: a tripped rollout switch means flame left the burner area.
Find a local HVAC pro →§4Other Lennox codes
Improper main ground, OR line voltage below 90 volts. Control will not respond to a heat call until voltage rises above 95 volts.
Alternating slow flashLennoxWatchguard 1 hour: burners failed to ignite or lost flame 5 times during a single heating demand.
Board failure patternLennoxCircuit board failure or control wired incorrectly.
Red fast flash, green slow flashLennoxMain power polarity reversed. Switch line and neutral.
Red off, green slow flashLennoxPressure prove switch open, OR blocked inlet/exhaust vent, OR pressure switch closed before the combustion air inducer started.
Red slow flash, green fast flashLennoxLow flame signal: measures below 1.5 microamps. Replace flame sense rod.