Watchguard 1 hour: burners failed to ignite or lost flame 5 times during a single heating demand.
§1Likely causes
- Burners failing to ignite
- Flame lost repeatedly
§2Safe DIY steps
- Confirm the gas supply to the furnace is on
- Techniciandiagnose ignition and flame sensing
§3When to call a pro
Call a licensed HVAC technician: if the furnace enters Watchguard again.
Find a local HVAC pro →§4Other Lennox codes
Improper main ground, OR line voltage below 90 volts. Control will not respond to a heat call until voltage rises above 95 volts.
Board failure patternLennoxCircuit board failure or control wired incorrectly.
Red fast flash, green slow flashLennoxMain power polarity reversed. Switch line and neutral.
Red off, green slow flashLennoxPressure prove switch open, OR blocked inlet/exhaust vent, OR pressure switch closed before the combustion air inducer started.
Red on, green slow flashLennoxRollout switch open, OR 12-pin connector improperly attached.
Red slow flash, green fast flashLennoxLow flame signal: measures below 1.5 microamps. Replace flame sense rod.