Amana EE0: Furnace lockout after an excessive number of ignition retries (3 total)

Source: Amana manual (PDF) (opens in a new tab) ↗ · Updated

Status codeEE0Amana
What does Amana EE0 mean?

Furnace lockout after an excessive number of ignition retries (3 total): flame was not established, or flame was lost after it was established.

Homeowner part this code names: furnace hot surface igniter.

Search on Amazon

Opens an Amazon search for that name. Check the size against your manual. As an Amazon Associate I earn from qualifying purchases.

How it shows: 7-segment display on a *CVC96 or *MVC96 two-stage furnace covered by IOG-2015L, including Amana AMVC96 and ACVC96: EE0

Amana EE0 on the *CVC96 / *MVC96 chart in IOG-2015L is a lockout after 3 ignition retries. Flame was never established, or it was lost after it was established. The chart says to correct a gas interruption, then a technician checks the front cover pressure switch and drainage, the igniter, the flame sensor, the flue, and the induced draft blower. The manual also says the control can try again after one hour, and will return to lockout if the cause is still there. This is the two-stage family, including Amana AMVC96 and ACVC96. It is a different document from the Goodman GR9S96 single-stage guide.

Likely causes

  • Gas supply interruption
  • Front cover pressure switch or condensate drainage problem
  • Igniter that needs replacement or realignment
  • Flame sensor coated or oxidized
  • Blocked flue piping, or piping with the wrong length, elbows or termination
  • Induced draft blower not performing properly

Safe checks for EE0

  1. Confirm the gas supply to the furnace is on
  2. The manual says an EE0 lockout can reset after one hour, after a power interruption, or after the thermostat is lowered for 1 to 20 seconds. If the original problem is still there, the control returns to lockout
  3. Techniciancheck the front cover pressure switch and drainage, realign or replace the igniter, clean the flame sensor if it is coated or oxidized, check the flue, and check the induced draft blower
Safety firstIf you smell gas, do not touch any electrical switch or use a phone in the building; leave immediately and call your gas supplier from outside. Turn off electrical power at the furnace switch or breaker before opening any panel, and never bypass or jumper a limit, rollout or pressure switch. Gas valve, burner, venting, wiring and control-board work should be done by a licensed HVAC technician.

Capacitors can hold a charge after the power is off. Safety terms.

When to call a pro

Call a licensed HVAC technician if EE0 returns after the gas supply is confirmed. This chart is the two-stage *CVC96 / *MVC96 guide, not the single-stage GR9S96 list.

Find a Amana dealer (official locator, opens in a new tab) ↗

Email me this fix

We save your email and this page. Nothing is emailed. We'll only use your email for this request.

Privacy. Deletion requests go to the address on that page.

Request a filter and maintenance reminder

We save your email, this page, and the interval you pick. Nothing is emailed. We'll only use your email for this request.

Privacy. Deletion requests go to the address on that page.

Parts & tools for this fix

Taken from this code's causes or steps. A search link opens Amazon results and does not confirm a fit. Check the model number in the manual.

Furnace flame sensor: guide

In this code: Flame sensor coated or oxidized

See the guide for what to look for when buying one.

Thermostat: guide

In this code: The manual says an EE0 lockout can reset after one hour, after a power interruption, or after the thermostat is lowered for 1 to 20 seconds. If the original problem is…

See the guide for what to look for when buying one.

Nut driver set: guide

In this code: Panels and parts on a furnace are held by hex-head screws; a nut driver grips them without stripping.

See the guide for what to look for when buying one.

Furnace pressure switch: guide

In this code: Front cover pressure switch or condensate drainage problem

This one is for a technician to test or replace, so we only explain it and do not link to buy it.

Furnace inducer (draft) motor: guide

In this code: Induced draft blower not performing properly

This one is for a technician to test or replace, so we only explain it and do not link to buy it.

As an Amazon Associate I earn from qualifying purchases.Affiliate disclosure

Related Amana codes

All Amana codes →Browse every code