Primary or secondary limit switch open. Limit must close within 3 minutes or the unit goes into 1-hour Watchguard.
§1Likely causes
- Limit switch open (overheating condition)
§2Safe DIY steps
- Turn off power and check the air filter; replace if dirty
- Techniciandiagnose why the limit opened
§3When to call a pro
Call a licensed HVAC technician: if the code repeats or the unit enters Watchguard.
Find a local HVAC pro →§4Other Lennox codes
Improper main ground, OR line voltage below 90 volts. Control will not respond to a heat call until voltage rises above 95 volts.
Alternating slow flashLennoxWatchguard 1 hour: burners failed to ignite or lost flame 5 times during a single heating demand.
Board failure patternLennoxCircuit board failure or control wired incorrectly.
Red fast flash, green slow flashLennoxMain power polarity reversed. Switch line and neutral.
Red off, green slow flashLennoxPressure prove switch open, OR blocked inlet/exhaust vent, OR pressure switch closed before the combustion air inducer started.
Red on, green slow flashLennoxRollout switch open, OR 12-pin connector improperly attached.