Status codeEALGoodman
What does Goodman EAL mean?
R-32 sensor reports a refrigerant leak: heating stops and only the fan runs while the furnace is in mitigation mode. The chart says normal operation returns once a leak is not detected and the 5-minute delay is over.
Call a pro: jump to when to call a pro Equipment type: furnace
How it shows: 7-segment display on a *R9S96, *D9S96 or *R9S92 single-stage furnace in IOG-2037B: EAL
Likely causes
- R-32 sensor reports a refrigerant leak, so the furnace stays in mitigation mode
Safe checks for EAL
- If heat has stopped and only the fan is running, write down EAL and leave the panels on
- Technicianthe chart says to investigate the indoor coil for a refrigerant leak. The furnace resumes normal operation once a leak is not detected and the 5-minute delay is over
Safety firstIf you smell gas, do not touch any electrical switch or use a phone in the building; leave immediately and call your gas supplier from outside. Turn off electrical power at the furnace switch or breaker before opening any panel, and never bypass or jumper a limit, rollout or pressure switch. Gas valve, burner, venting, wiring and control-board work should be done by a licensed HVAC technician.
Capacitors can hold a charge after the power is off. Safety terms.
When to call a pro
Call a licensed HVAC technician. A refrigerant leak is not a filter change or a breaker reset.
Find a Goodman dealer (official locator, opens in a new tab) ↗Email me this fix