Furnace Blowing Cold Air: Common Causes

By The Fault Code editorial team · Updated 2026-10-23

Short answer

A furnace blowing cold air usually means the blower is running while the burners are not. That can be a thermostat fan set to ON instead of AUTO, or a fault where the burners shut down but the blower keeps running to cool the furnace, such as an open limit switch or a failed ignition. Check the thermostat and filter, then read the control board code.

Causes and codes

What’s happeningLikely reasonRelated codes
Air is cool between heating cyclesThermostat fan set to ON (continuous)none
Blower runs, no heatLimit switch open, blower runs to cool the furnaceGoodman EE3, Carrier 33
Burners try, then stopIgnition or flame sensing failureCarrier 34, Rheem 11, Trane E2.1
No burner attemptPressure switch or lockoutGoodman EE2, Carrier 14

The Goodman EE3 entry in its manual notes the circulator blower runs continuously with no heat when the primary limit is open, and Carrier says the blower runs for 4 minutes or until the open switch closes for code 33.

Safe checks

  1. Thermostat: set to HEAT, fan to AUTO, setpoint above room temperature.
  2. Replace a dirty filter and open registers.
  3. Read and look up the control board code.

Safety first: If you smell gas, don’t touch light switches or use a phone inside. Leave the building and call your gas utility from outside. Turn off power to the furnace before opening any panel, and never bypass or jumper a safety switch. Gas, venting, wiring and control-board work is for a licensed HVAC technician.

§FFAQ

Why does my furnace blow cold air at the start?

Furnace controls use a blower on-delay and off-delay (the Carrier manual describes both), so the blower timing does not exactly match the burners. Brief cool air at the end of a cycle can be the normal off-delay. If air stays cold, check the code.

Can a dirty filter make a furnace blow cold air?

A restricted filter can overheat the furnace and open the limit switch, stopping the burners while the blower keeps running.