Rheem 10: One-hour lockout, caused by repeated failed ignition (11), water sensed (59), dead blower (61), internal fault (93), flame lost 5 times (13) or unexpected flame (14)

Ref. RHEEM-10 · From the Rheem furnace manual · Updated 2026-10-23

Status code10Rheem
What it means

One-hour lockout, caused by repeated failed ignition (11), water sensed (59), dead blower (61), internal fault (93), flame lost 5 times (13) or unexpected flame (14).

Call a profurnace
How it shows: Dual 7-segment display: 10 (alternates with the fault that caused it)

Find a local HVAC pro →

§1Likely causes

  • See the code shown alternately with 10

§2Safe DIY steps

  1. Read the second code that alternates with 10 and follow that code
  2. Lockout clears when the cause is corrected and power is cycled off and on
Safety firstIf you smell gas, do not touch any electrical switch or use a phone in the building; leave immediately and call your gas supplier from outside. Turn off electrical power at the furnace switch or breaker before opening any panel, and never bypass or jumper a limit, rollout or pressure switch. Gas valve, burner, venting, wiring and control-board work should be done by a licensed HVAC technician.

§3When to call a pro

Call a licensed HVAC technician: if the furnace keeps entering lockout.